Skip to main content

Cornelis Technical Documentation

BMC Firmware

Download PDF

Preface

This document provides an overview of the changes introduced in this release. References to more detailed information are provided where necessary. The information contained in this document is intended as supplemental information only; it should be used in conjunction with the documentation provided for each component.

Software License Agreement

The software is provided under license agreements and may contain third-party software under separate third-party licensing. Refer to the license files provided with the software for specific details.

If You Need Help

Technical support for all Cornelis products is available 24 hours a day, 365 days a year.

For additional details:

New in This Release

The following features are new in this release:

  • Maintenance Updates

Firmware Components

This release contains the firmware components listed in the following table.

Firmware Components

Description

File Name

Version

BMC Firmware

CN5000.BMCFirmware-12.4.0.0.10.pkg

12.4.0



System Requirements

This section lists the supported hardware.

Supported Hardware

The following tables list the hardware supported in this release.

Switch Products

Hardware

Description

CN5000 Switch

CN5000 Switch, 48-Port, CN5SWE48G2AF

240/277 VAC in, Dual Power Supply, Air-Cooled, Fan-to-Port

CN5000 Switch, 48-Port, CN5SWE48G2AP

240/277 VAC in, Dual Power Supply, Air-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48G2WF

240/277 VAC in, Dual Power Supply, Liquid-Cooled, Fan-to-Port

CN5000 Switch, 48-Port, CN5SWE48G2WP

240/277 VAC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48D2AP

48 VDC in, Dual Power Supply, Air-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48D2WP

48 VDC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan

CN5000 Director Class Switch and Components

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAB

240/277 VAC in, Air-Cooled, Base Chassis

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAC

240/277 VAC in, Air-Cooled, FRU Chassis

CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48A

48-Port, Air-Cooled

CN5000 Director Class Switch, Spine Module, CN5SWDSP01A

Air-Cooled

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWB

240/277 VAC in, Liquid-Cooled, Base Chassis

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWC

240/277 VAC in, Liquid-Cooled, FRU Chassis

CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48W

48-Port, Liquid-Cooled

CN5000 Director Class Switch, Spine Module, CN5SWDSP01W

Liquid-Cooled



Installation Requirements

Refer to the CN5000 Maintenance and Troubleshooting Guide for instructions to update the switch firmware.

Best Practices
  • To obtain the most recent functional and security updates, Cornelis recommends that you download and install the latest versions of the CN5000 Omni-Path software and firmware. Software and Documentation are found in the Cornelis Customer Center.

  • To ensure optimal performance in your CN5000 fabric, it is important to review the Cornelis performance tuning recommendations in the CN5000 Performance Tuning Guide.

Issues

This section lists the resolved and open issues.

Resolved Issues

The following table lists issues that are resolved in this release.

Issues Resolved in this Release

ID

Description

Resolved in Release

STL-76775

Ports that have been disabled may be re-enabled after a reboot of the switch.

12.4.0



Open Issues

The following table lists the open issues for this release.

Open Issues

ID

Description

Workaround

STL-78122

After restarting the Fabric Manager, the switch does not rejoin IPoIB multicast groups.

Restart IPoIB on the switch by disabling and re-enabling it:

network ib --disable
network ib --enable

STL-77842

nmap port scan of IPoIB address causes switch instability.

Do not run nmap port scan against the switch over the IPoIB network.

STL-77720

The switch IPoIB interface (ib0) fails to establish carrier and remains down when the fabric's default multicast group MTU is configured above 4096 bytes (for example, 10K MTU for Accelerated IP/AIP support).

None.

STL-77407

Unable to delete IPoIB IPv6 address after adding it.

None.

STL-76677

When removing SSH keys, partial matches of the comment could remove more keys than intended.

When removing an SSH key, use the entire comment of the key.



Product Limitations

This release has the following product limitations:

  • The OpenBMC Web User Interface is not supported.

  • Updating the switch components (BMC/ASIC) in-band with the firmware update tool fails if the switch is running firmware older 12.2.x. You must update the firmware to 12.2 or greater before using in-band firmware updates.

Download PDF

Preface

This document provides an overview of the changes introduced in this release. References to more detailed information are provided where necessary. The information contained in this document is intended as supplemental information only; it should be used in conjunction with the documentation provided for each component.

Software License Agreement

The software is provided under license agreements and may contain third-party software under separate third-party licensing. Refer to the license files provided with the software for specific details.

If You Need Help

Technical support for all Cornelis products is available 24 hours a day, 365 days a year.

For additional details:

New in This Release

The following features are new in this release:

  • Maintenance Updates

Firmware Components

This release contains the firmware components listed in the following table.

Firmware Components

Description

File Name

Version

BMC Firmware

CN5000.BMCFirmware-12.3.0.0.30.pkg

12.3.0



System Requirements

This section lists the supported hardware.

Supported Hardware

The following tables list the hardware supported in this release.

Switch Products

Hardware

Description

CN5000 Switch

CN5000 Switch, 48-Port, CN5SWE48G2AF

240/277 VAC in, Dual Power Supply, Air-Cooled, Fan-to-Port

CN5000 Switch, 48-Port, CN5SWE48G2AP

240/277 VAC in, Dual Power Supply, Air-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48G2WF

240/277 VAC in, Dual Power Supply, Liquid-Cooled, Fan-to-Port

CN5000 Switch, 48-Port, CN5SWE48G2WP

240/277 VAC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48D2AP

48 VDC in, Dual Power Supply, Air-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48D2WP

48 VDC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan

CN5000 Director Class Switch and Components

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAB

240/277 VAC in, Air-Cooled, Base Chassis

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAC

240/277 VAC in, Air-Cooled, FRU Chassis

CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48A

48-Port, Air-Cooled

CN5000 Director Class Switch, Spine Module, CN5SWDSP01A

Air-Cooled

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWB

240/277 VAC in, Liquid-Cooled, Base Chassis

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWC

240/277 VAC in, Liquid-Cooled, FRU Chassis

CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48W

48-Port, Liquid-Cooled

CN5000 Director Class Switch, Spine Module, CN5SWDSP01W

Liquid-Cooled



Installation Requirements

Refer to the CN5000 Maintenance and Troubleshooting Guide for instructions to update the switch firmware.

Best Practices
  • To obtain the most recent functional and security updates, Cornelis recommends that you download and install the latest versions of the CN5000 Omni-Path software and firmware. Software and Documentation are found in the Cornelis Customer Center.

  • To ensure optimal performance in your CN5000 fabric, it is important to review the Cornelis performance tuning recommendations in the CN5000 Performance Tuning Guide.

Issues

This section lists the resolved and open issues.

Resolved Issues

The following table lists issues that are resolved in this release.

Issues Resolved in this Release

ID

Description

Resolved in Release

STL-76490

Port configuration changes are not consistently applied when bouncing a link.

12.3.0

STL-73311

If a server's SSH host identification (host key) is changed, such as by reinstalling the OS or routing a hostname to a different server, switch maintenance tasks run from the switch that use file transfers (such as firmware udpate and capture state copy) can fail with an error message about SSH usage.

12.3.0



Open Issues

The following table lists the open issues for this release.

Open Issues

ID

Description

Workaround

STL-78122

After restarting the Fabric Manager, the switch does not rejoin IPoIB multicast groups.

Restart IPoIB on the switch by disabling and re-enabling it:

network ib --disable
network ib --enable

STL-77842

nmap port scan of IPoIB address causes switch instability.

Do not run nmap port scan against the switch over the IPoIB network.

STL-77720

The switch IPoIB interface (ib0) fails to establish carrier and remains down when the fabric's default multicast group MTU is configured above 4096 bytes (for example, 10K MTU for Accelerated IP/AIP support).

None.

STL-77407

Unable to delete IPoIB IPv6 address after adding it.

None.

STL-76775

Ports that have been disabled may be re-enabled after a reboot of the switch.

Disable the ports again after a switch reboot.

STL-76677

When removing SSH keys, partial matches of the comment could remove more keys than intended.

When removing an SSH key, use the entire comment of the key.



Product Limitations

This release has the following product limitations:

  • The OpenBMC Web User Interface is not supported.

  • Updating the switch components (BMC/ASIC) in-band with the firmware update tool fails if the switch is running firmware older 12.2.x. You must update the firmware to 12.2 or greater before using in-band firmware updates.

Download PDF

Preface

This document provides an overview of the changes introduced in this release. References to more detailed information are provided where necessary. The information contained in this document is intended as supplemental information only; it should be used in conjunction with the documentation provided for each component.

Software License Agreement

The software is provided under license agreements and may contain third-party software under separate third-party licensing. Refer to the license files provided with the software for specific details.

If You Need Help

Technical support for all Cornelis products is available 24 hours a day, 365 days a year.

For additional details:

New in This Release

The following features are new in this release:

  • Support for Redfish API

  • Maintenance Updates

Firmware Components

This release contains the firmware components listed in the following table.

Firmware Components

Description

File Name

Version

BMC Firmware

CN5000.BMCFirmware-12.2.0.0.26.pkg

12.2.0



System Requirements

This section lists the supported hardware.

Supported Hardware

The following tables list the hardware supported in this release.

Switch Products

Hardware

Description

CN5000 Switch

CN5000 Switch, 48-Port, CN5SWE48G2AF

240/277 VAC in, Dual Power Supply, Air-Cooled, Fan-to-Port

CN5000 Switch, 48-Port, CN5SWE48G2AP

240/277 VAC in, Dual Power Supply, Air-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48G2WF

240/277 VAC in, Dual Power Supply, Liquid-Cooled, Fan-to-Port

CN5000 Switch, 48-Port, CN5SWE48G2WP

240/277 VAC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48D2AP

48 VDC in, Dual Power Supply, Air-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48D2WP

48 VDC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan

CN5000 Director Class Switch and Components

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAB

240/277 VAC in, Air-Cooled, Base Chassis

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAC

240/277 VAC in, Air-Cooled, FRU Chassis

CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48A

48-Port, Air-Cooled

CN5000 Director Class Switch, Spine Module, CN5SWDSP01A

Air-Cooled

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWB

240/277 VAC in, Liquid-Cooled, Base Chassis

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWC

240/277 VAC in, Liquid-Cooled, FRU Chassis

CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48W

48-Port, Liquid-Cooled

CN5000 Director Class Switch, Spine Module, CN5SWDSP01W

Liquid-Cooled



Installation Requirements

Refer to the CN5000 Maintenance and Troubleshooting Guide for instructions to update the switch firmware.

Best Practices
  • To obtain the most recent functional and security updates, Cornelis recommends that you download and install the latest versions of the CN5000 Omni-Path software and firmware. Software and Documentation are found in the Cornelis Customer Center.

  • To ensure optimal performance in your CN5000 fabric, it is important to review the Cornelis performance tuning recommendations in the CN5000 Performance Tuning Guide.

Issues

This section lists the resolved and open issues.

Resolved Issues

The following table lists issues that are resolved in this release.

Issues Resolved in this Release

ID

Description

Resolved in Release

STL-76777

Using the network ip del command on a static IP address does not work.

12.2.0

STL-76486

Port configuration changes are not consistently applied when bouncing a link.

12.2.0

STL-75381

Prior to a reboot, the secondary Management Module (MM) may not reflect the current status of the image that should be booted after a BMC update.

12.2.0

STL-72221

Switch in-band management including configuring an IPoIB interface is not available. 

12.2.0



Open Issues

The following table lists the open issues for this release.

Open Issues

ID

Description

Workaround

STL-78122

After restarting the Fabric Manager, the switch does not rejoin IPoIB multicast groups.

Restart IPoIB on the switch by disabling and re-enabling it:

network ib --disable
network ib --enable

STL-77842

nmap port scan of IPoIB address causes switch instability.

Do not run nmap port scan against the switch over the IPoIB network.

STL-77720

The switch IPoIB interface (ib0) fails to establish carrier and remains down when the fabric's default multicast group MTU is configured above 4096 bytes (for example, 10K MTU for Accelerated IP/AIP support).

None.

STL-77407

Unable to delete IPoIB IPv6 address after adding it.

None.

STL-76775

Ports that have been disabled may be re-enabled after a reboot of the switch.

Disable the ports again after a switch reboot.

STL-76677

When removing SSH keys, partial matches of the comment could remove more keys than intended.

When removing an SSH key, use the entire comment of the key.

STL-76490

Port configuration changes are not consistently applied when bouncing a link.

Explicitly disable the link and then enable the link for the changes to take effect.

STL-73311

If a server's SSH host identification (host key) is changed, such as by reinstalling the OS or routing a hostname to a different server, switch maintenance tasks run from the switch that use file transfers (such as firmware udpate and capture state copy) can fail with an error message about SSH usage.

Use scp for file transfers from the server into the switch.

  • For firmware update, copy the *.pkg to /tmp/pldm-images on the switch.

  • For state dumps, scp from the switch's state dump files located in /usr/local/asicdump/.



Product Limitations

This release has the following product limitations:

  • The OpenBMC Web User Interface is not supported.

  • Updating the switch components (BMC/ASIC) in-band with the firmware update tool fails if the switch is running firmware older 12.2.x. You must update the firmware to 12.2 or greater before using in-band firmware updates.

Download PDF

Preface

This document provides an overview of the changes introduced in this release. References to more detailed information are provided where necessary. The information contained in this document is intended as supplemental information only; it should be used in conjunction with the documentation provided for each component.

Software License Agreement

The software is provided under license agreements and may contain third-party software under separate third-party licensing. Refer to the license files provided with the software for specific details.

If You Need Help

Technical support for all Cornelis products is available 24 hours a day, 365 days a year.

For additional details:

New in This Release

The following features are new in this release:

  • Maintenance Updates

Firmware Components

This release contains the firmware components listed in the following table.

Firmware Components

Description

File Name

Version

BMC Firmware

CN5000.BMCFirmware-12.1.2.0.3.pkg

12.1.2



System Requirements

This section lists the supported hardware.

Supported Hardware

The following tables list the hardware supported in this release.

Switch Products

Hardware

Description

CN5000 Switch

CN5000 Switch, 48-Port, CN5SWE48G2AF

240/277 VAC in, Dual Power Supply, Air-Cooled, Fan-to-Port

CN5000 Switch, 48-Port, CN5SWE48G2AP

240/277 VAC in, Dual Power Supply, Air-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48G2WF

240/277 VAC in, Dual Power Supply, Liquid-Cooled, Fan-to-Port

CN5000 Switch, 48-Port, CN5SWE48G2WP

240/277 VAC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48D2AP

48 VDC in, Dual Power Supply, Air-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48D2WP

48 VDC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan

CN5000 Director Class Switch and Components

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAB

240/277 VAC in, Air-Cooled, Base Chassis

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAC

240/277 VAC in, Air-Cooled, FRU Chassis

CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48A

48-Port, Air-Cooled

CN5000 Director Class Switch, Spine Module, CN5SWDSP01A

Air-Cooled

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWB

240/277 VAC in, Liquid-Cooled, Base Chassis

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWC

240/277 VAC in, Liquid-Cooled, FRU Chassis

CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48W

48-Port, Liquid-Cooled

CN5000 Director Class Switch, Spine Module, CN5SWDSP01W

Liquid-Cooled



Installation Requirements

Refer to the CN5000 Maintenance and Troubleshooting Guide for instructions to update the switch firmware.

Best Practices
  • To obtain the most recent functional and security updates, Cornelis recommends that you download and install the latest versions of the CN5000 Omni-Path software and firmware. Software and Documentation are found in the Cornelis Customer Center.

  • To ensure optimal performance in your CN5000 fabric, it is important to review the Cornelis performance tuning recommendations in the CN5000 Performance Tuning Guide.

Issues

This section lists the resolved and open issues.

Resolved Issues

The following table lists issues that are resolved in this release.

Issues Resolved in this Release

ID

Description

Resolved in Release

STL-77092

Liquid-cooled switches running firmware BMC 12.1.1.0.9 and ASIC 12_1_1_0_6 display Fault detected in VR errors and Board hardware status: NOT_GOOD warnings during hardware checks.

12.1.1.1

STL-75426

When custom users are added to the DCS, they are not synchronized between the two Management Modules (MM).

12.1.0

STL-75420

When updating the BMC firmware on the DCS, if the selected firmware image number (1 or 2) of a board is not set to same firmware image number as the primary MM, then the firmware update will not propagate to the out of sync board/boards.

12.1.0

STL-75396

If the Real-Time Clock (RTC) has lost power, then the Network Time Protocol (NTP) cannot be set.

12.1.2

STL-75258

When running the switch CLI capture state take command, a message states to wait for 5 minutes for the statedump to complete. However, the statedump may take longer than 5 minutes.

12.1.0

STL-75248

When rebooting individual cards using the switch CLI reboot command, that CLI session can no longer connect to the chassis hardware.

12.1.1

STL-75223

The LED colors and statuses reported by switch CLI hardware led command do not match the physical LEDs.

12.1.0

STL-74875

When executing network chassis gateway <IP Address>, the command will set the chassis IP instead of a gateway. The chassis does not support setting a gateway.

12.1.0

STL-74852

The switch CLI watch command does not operate properly for DCS spine and leaf cards.

12.1.1

STL-74845

The switch CLI hardware led command does not show the state of the LEDs in a DCS.

12.1.0

STL-74450

Setting the NTP server on the primary Management Module (MM) does not propagate to the secondary MM.

12.1.0

STL-74386

When a new user is created within the admin group and you switch to the new user, they will not have access to the admin commands.

12.1.0

STL-74368

Aborting while creating a new user will create the user, but the user will not be accessible.

12.1.0

STL-74363

The beacon command does not cause the beacon LED to flash.

12.1.0

STL-73895

The capture state command fails with with Error running SCP command.

12.1.0

STL-73885

The port show command does not display subdivided child ports.

12.1.0

STL-73477

The capture port command fails with an Invalid port name error.

12.1.0

STL-73431

Pressing and holding Ctrl+C during command execution can cause the CLI to become non-responsive.

12.1.0

STL-73400

Rebooting the switch in a non-interactive SSH session may result in the following error:

EOFError: Ran out of input
Lost Communication with server

12.1.0

STL-73355

In the port show switch command, TX Packet Count and RX Packet Count display inaccurate values.

12.1.0

STL-73029

BEL DC power supplies VOUT_MODE command returns incorrect results.

12.1.0

STL-72795

Commands showing the QSFP max temperature will show an invalid number for the QSFP max temperature if no cables are installed.

12.1.0

STL-72706

CLI hang occurs if CTRL+C is used during password entry for SCP for firmware update.

12.1.0

STL-72570

IPv4 addresses display incorrectly when using the opasmaquery command.

12.1.0

STL-72273

Mistyped commands may cause the CLI to stop responding.

12.1.0

STL-72226

Switch CLI log command may take 6-8 minutes to complete.

12.1.0



Open Issues

The following table lists the open issues for this release.

Open Issues

ID

Description

Workaround

STL-76777

Using the network ip del command on a static IP address does not work.

Reboot the BMC to clear the static IP.

STL-76775

Ports that have been disabled may be re-enabled after a reboot of the switch.

Disable the ports again after a switch reboot.

STL-76677

When removing SSH keys, partial matches of the comment could remove more keys than intended.

When removing an SSH key, use the entire comment of the key.

STL-76490

STL-76486

Port configuration changes are not consistently applied when bouncing a link.

Explicitly disable the link and then enable the link for the changes to take effect.

STL-75381

Prior to a reboot, the secondary Management Module (MM) may not reflect the current status of the image that should be booted after a BMC update.

Prior to a reboot of the secondary MM, select the image to be booted using firmware select bmc <1 or 2>.

STL-73311

If a server's SSH host identification (host key) is changed, such as by reinstalling the OS or routing a hostname to a different server, switch maintenance tasks run from the switch that use file transfers (such as firmware udpate and capture state copy) can fail with an error message about SSH usage.

Use scp for file transfers from the server into the switch.

  • For firmware update, copy the *.pkg to /tmp/pldm-images on the switch.

  • For state dumps, scp from the switch's state dump files located in /usr/local/asicdump/.

STL-72221

Switch in-band management including configuring an IPoIB interface is not available. 

Use the switch's Ethernet or serial connections for switch management.



Product Limitations

This release has the following product limitations:

  • The OpenBMC Web User Interface is not supported.

Download PDF

Preface

This document provides an overview of the changes introduced in this release. References to more detailed information are provided where necessary. The information contained in this document is intended as supplemental information only; it should be used in conjunction with the documentation provided for each component.

Software License Agreement

The software is provided under license agreements and may contain third-party software under separate third-party licensing. Refer to the license files provided with the software for specific details.

If You Need Help

Technical support for all Cornelis products is available 24 hours a day, 365 days a year.

For additional details:

New in This Release

The following features are new in this release:

  • Maintenance Updates

Firmware Components

This release contains the firmware components listed in the following table.

Firmware Components

Description

File Name

Version

BMC Firmware

CN5000.BMCFirmware-12.1.1.1.2.pkg

12.1.1.1



System Requirements

This section lists the supported hardware.

Supported Hardware

The following tables list the hardware supported in this release.

Switch Products

Hardware

Description

CN5000 Switch

CN5000 Switch, 48-Port, CN5SWE48G2AF

240/277 VAC in, Dual Power Supply, Air-Cooled, Fan-to-Port

CN5000 Switch, 48-Port, CN5SWE48G2AP

240/277 VAC in, Dual Power Supply, Air-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48G2WF

240/277 VAC in, Dual Power Supply, Liquid-Cooled, Fan-to-Port

CN5000 Switch, 48-Port, CN5SWE48G2WP

240/277 VAC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48D2AP

48 VDC in, Dual Power Supply, Air-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48D2WP

48 VDC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan

CN5000 Director Class Switch and Components

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAB

240/277 VAC in, Air-Cooled, Base Chassis

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAC

240/277 VAC in, Air-Cooled, FRU Chassis

CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48A

48-Port, Air-Cooled

CN5000 Director Class Switch, Spine Module, CN5SWDSP01A

Air-Cooled

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWB

240/277 VAC in, Liquid-Cooled, Base Chassis

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWC

240/277 VAC in, Liquid-Cooled, FRU Chassis

CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48W

48-Port, Liquid-Cooled

CN5000 Director Class Switch, Spine Module, CN5SWDSP01W

Liquid-Cooled



Installation Requirements

Refer to the CN5000 Maintenance and Troubleshooting Guide for instructions to update the switch firmware.

Best Practices
  • To obtain the most recent functional and security updates, Cornelis recommends that you download and install the latest versions of the CN5000 Omni-Path software and firmware. Software and Documentation are found in the Cornelis Customer Center.

  • To ensure optimal performance in your CN5000 fabric, it is important to review the Cornelis performance tuning recommendations in the CN5000 Performance Tuning Guide.

Issues

This section lists the resolved and open issues.

Resolved Issues

The following table lists issues that are resolved in this release.

Issues Resolved in this Release

ID

Description

Resolved in Release

STL-77092

Liquid-cooled switches running firmware BMC 12.1.1.0.9 and ASIC 12_1_1_0_6 display Fault detected in VR errors and Board hardware status: NOT_GOOD warnings during hardware checks.

12.1.1.1

STL-75426

When custom users are added to the DCS, they are not synchronized between the two Management Modules (MM).

12.1.0

STL-75420

When updating the BMC firmware on the DCS, if the selected firmware image number (1 or 2) of a board is not set to same firmware image number as the primary MM, then the firmware update will not propagate to the out of sync board/boards.

12.1.0

STL-75258

When running the switch CLI capture state take command, a message states to wait for 5 minutes for the statedump to complete. However, the statedump may take longer than 5 minutes.

12.1.0

STL-75248

When rebooting individual cards using the switch CLI reboot command, that CLI session can no longer connect to the chassis hardware.

12.1.1

STL-75223

The LED colors and statuses reported by switch CLI hardware led command do not match the physical LEDs.

12.1.0

STL-74875

When executing network chassis gateway <IP Address>, the command will set the chassis IP instead of a gateway. The chassis does not support setting a gateway.

12.1.0

STL-74852

The switch CLI watch command does not operate properly for DCS spine and leaf cards.

12.1.1

STL-74845

The switch CLI hardware led command does not show the state of the LEDs in a DCS.

12.1.0

STL-74450

Setting the NTP server on the primary Management Module (MM) does not propagate to the secondary MM.

12.1.0

STL-74386

When a new user is created within the admin group and you switch to the new user, they will not have access to the admin commands.

12.1.0

STL-74368

Aborting while creating a new user will create the user, but the user will not be accessible.

12.1.0

STL-74363

The beacon command does not cause the beacon LED to flash.

12.1.0

STL-73895

The capture state command fails with with Error running SCP command.

12.1.0

STL-73885

The port show command does not display subdivided child ports.

12.1.0

STL-73477

The capture port command fails with an Invalid port name error.

12.1.0

STL-73431

Pressing and holding Ctrl+C during command execution can cause the CLI to become non-responsive.

12.1.0

STL-73400

Rebooting the switch in a non-interactive SSH session may result in the following error:

EOFError: Ran out of input
Lost Communication with server

12.1.0

STL-73355

In the port show switch command, TX Packet Count and RX Packet Count display inaccurate values.

12.1.0

STL-73029

BEL DC power supplies VOUT_MODE command returns incorrect results.

12.1.0

STL-72795

Commands showing the QSFP max temperature will show an invalid number for the QSFP max temperature if no cables are installed.

12.1.0

STL-72706

CLI hang occurs if CTRL+C is used during password entry for SCP for firmware update.

12.1.0

STL-72570

IPv4 addresses display incorrectly when using the opasmaquery command.

12.1.0

STL-72273

Mistyped commands may cause the CLI to stop responding.

12.1.0

STL-72226

Switch CLI log command may take 6-8 minutes to complete.

12.1.0



Open Issues

The following table lists the open issues for this release.

Open Issues

ID

Description

Workaround

STL-76777

Using the network ip del command on a static IP address does not work.

Reboot the BMC to clear the static IP.

STL-76775

Ports that have been disabled may be re-enabled after a reboot of the switch.

Disable the ports again after a switch reboot.

STL-76677

When removing SSH keys, partial matches of the comment could remove more keys than intended.

When removing an SSH key, use the entire comment of the key.

STL-76490

Port configuration changes are not consistently applied when bouncing a link.

Explicitly disable the link and then enable the link for the changes to take effect.

STL-76486

When making port configuration changes on a DCS, bouncing the link alone does not apply the new configuration.

Explicitly disable the link and then enable the link for the changes to take effect.

STL-75396

If the Real-Time Clock (RTC) has lost power, then the Network Time Protocol (NTP) cannot be set.

Contact support@cornelis.com.

STL-75381

Prior to a reboot, the secondary Management Module (MM) may not reflect the current status of the image that should be booted after a BMC update.

Prior to a reboot of the secondary MM, select the image to be booted using firmware select bmc <1 or 2>.

STL-73311

If a server's SSH host identification (host key) is changed, such as by reinstalling the OS or routing a hostname to a different server, switch maintenance tasks run from the switch that use file transfers (such as firmware udpate and capture state copy) can fail with an error message about SSH usage.

Use scp for file transfers from the server into the switch.

  • For firmware update, copy the *.pkg to /tmp/pldm-images on the switch.

  • For state dumps, scp from the switch's state dump files located in /usr/local/asicdump/.

STL-72221

Switch in-band management including configuring an IPoIB interface is not available. 

Use the switch's Ethernet or serial connections for switch management.



Product Limitations

This release has the following product limitations:

  • The OpenBMC Web User Interface is not supported.

Download PDF

Preface

This document provides an overview of the changes introduced in this release. References to more detailed information are provided where necessary. The information contained in this document is intended as supplemental information only; it should be used in conjunction with the documentation provided for each component.

Software License Agreement

The software is provided under license agreements and may contain third-party software under separate third-party licensing. Refer to the license files provided with the software for specific details.

If You Need Help

Technical support for all Cornelis products is available 24 hours a day, 365 days a year.

For additional details:

New in This Release

The following features are new in this release:

  • Maintenance Updates

Firmware Components

This release contains the firmware components listed in the following table.

Firmware Components

Description

File Name

Version

BMC Firmware

CN5000.BMCFirmware-12.1.1.0.9.pkg

12.1.1.0



System Requirements

This section lists the supported hardware.

Supported Hardware

The following tables list the hardware supported in this release.

Switch Products

Hardware

Description

CN5000 Switch

CN5000 Switch, 48-Port, CN5SWE48G2AF

240/277 VAC in, Dual Power Supply, Air-Cooled, Fan-to-Port

CN5000 Switch, 48-Port, CN5SWE48G2AP

240/277 VAC in, Dual Power Supply, Air-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48G2WF

240/277 VAC in, Dual Power Supply, Liquid-Cooled, Fan-to-Port

CN5000 Switch, 48-Port, CN5SWE48G2WP

240/277 VAC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48D2AP

48 VDC in, Dual Power Supply, Air-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48D2WP

48 VDC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan

CN5000 Director Class Switch and Components

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAB

240/277 VAC in, Air-Cooled, Base Chassis

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAC

240/277 VAC in, Air-Cooled, FRU Chassis

CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48A

48-Port, Air-Cooled

CN5000 Director Class Switch, Spine Module, CN5SWDSP01A

Air-Cooled

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWB

240/277 VAC in, Liquid-Cooled, Base Chassis

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWC

240/277 VAC in, Liquid-Cooled, FRU Chassis

CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48W

48-Port, Liquid-Cooled

CN5000 Director Class Switch, Spine Module, CN5SWDSP01W

Liquid-Cooled



Installation Requirements

Refer to the CN5000 Maintenance and Troubleshooting Guide for instructions to update the switch firmware.

Best Practices
  • To obtain the most recent functional and security updates, Cornelis recommends that you download and install the latest versions of the CN5000 Omni-Path software and firmware. Software and Documentation are found in the Cornelis Customer Center.

  • To ensure optimal performance in your CN5000 fabric, it is important to review the Cornelis performance tuning recommendations in the CN5000 Performance Tuning Guide.

Issues

This section lists the resolved and open issues.

Resolved Issues

The following table lists issues that are resolved in this release.

Issues Resolved in this Release

ID

Description

Resolved in Release

STL-75426

When custom users are added to the DCS, they are not synchronized between the two Management Modules (MM).

12.1.0

STL-75420

When updating the BMC firmware on the DCS, if the selected firmware image number (1 or 2) of a board is not set to same firmware image number as the primary MM, then the firmware update will not propagate to the out of sync board/boards.

12.1.0

STL-75258

When running the switch CLI capture state take command, a message states to wait for 5 minutes for the statedump to complete. However, the statedump may take longer than 5 minutes.

12.1.0

STL-75248

When rebooting individual cards using the switch CLI reboot command, that CLI session can no longer connect to the chassis hardware.

12.1.1

STL-75223

The LED colors and statuses reported by switch CLI hardware led command do not match the physical LEDs.

12.1.0

STL-74875

When executing network chassis gateway <IP Address>, the command will set the chassis IP instead of a gateway. The chassis does not support setting a gateway.

12.1.0

STL-74852

The switch CLI watch command does not operate properly for DCS spine and leaf cards.

12.1.1

STL-74845

The switch CLI hardware led command does not show the state of the LEDs in a DCS.

12.1.0

STL-74450

Setting the NTP server on the primary Management Module (MM) does not propagate to the secondary MM.

12.1.0

STL-74386

When a new user is created within the admin group and you switch to the new user, they will not have access to the admin commands.

12.1.0

STL-74368

Aborting while creating a new user will create the user, but the user will not be accessible.

12.1.0

STL-74363

The beacon command does not cause the beacon LED to flash.

12.1.0

STL-73895

The capture state command fails with with Error running SCP command.

12.1.0

STL-73885

The port show command does not display subdivided child ports.

12.1.0

STL-73477

The capture port command fails with an Invalid port name error.

12.1.0

STL-73431

Pressing and holding Ctrl+C during command execution can cause the CLI to become non-responsive.

12.1.0

STL-73400

Rebooting the switch in a non-interactive SSH session may result in the following error:

EOFError: Ran out of input
Lost Communication with server

12.1.0

STL-73355

In the port show switch command, TX Packet Count and RX Packet Count display inaccurate values.

12.1.0

STL-73029

BEL DC power supplies VOUT_MODE command returns incorrect results.

12.1.0

STL-72795

Commands showing the QSFP max temperature will show an invalid number for the QSFP max temperature if no cables are installed.

12.1.0

STL-72706

CLI hang occurs if CTRL+C is used during password entry for SCP for firmware update.

12.1.0

STL-72570

IPv4 addresses display incorrectly when using the opasmaquery command.

12.1.0

STL-72273

Mistyped commands may cause the CLI to stop responding.

12.1.0

STL-72226

Switch CLI log command may take 6-8 minutes to complete.

12.1.0



Open Issues

The following table lists the open issues for this release.

Open Issues

ID

Description

Workaround

STL-76777

Using the network ip del command on a static IP address does not work.

Reboot the BMC to clear the static IP.

STL-76775

Ports that have been disabled may be re-enabled after a reboot of the switch.

Disable the ports again after a switch reboot.

STL-76677

When removing SSH keys, partial matches of the comment could remove more keys than intended.

When removing an SSH key, use the entire comment of the key.

STL-76490

Port configuration changes are not consistently applied when bouncing a link.

Explicitly disable the link and then enable the link for the changes to take effect.

STL-76486

When making port configuration changes on a DCS, bouncing the link alone does not apply the new configuration.

Explicitly disable the link and then enable the link for the changes to take effect.

STL-75396

If the Real-Time Clock (RTC) has lost power, then the Network Time Protocol (NTP) cannot be set.

Contact support@cornelis.com.

STL-75381

Prior to a reboot, the secondary Management Module (MM) may not reflect the current status of the image that should be booted after a BMC update.

Prior to a reboot of the secondary MM, select the image to be booted using firmware select bmc <1 or 2>.

STL-73311

If a server's SSH host identification (host key) is changed, such as by reinstalling the OS or routing a hostname to a different server, switch maintenance tasks run from the switch that use file transfers (such as firmware udpate and capture state copy) can fail with an error message about SSH usage.

Use scp for file transfers from the server into the switch.

  • For firmware update, copy the *.pkg to /tmp/pldm-images on the switch.

  • For state dumps, scp from the switch's state dump files located in /usr/local/asicdump/.

STL-72221

Switch in-band management including configuring an IPoIB interface is not available. 

Use the switch's Ethernet or serial connections for switch management.



Product Limitations

This release has the following product limitations:

  • The OpenBMC Web User Interface is not supported.

Download PDF

Preface

This document provides an overview of the changes introduced in this release. References to more detailed information are provided where necessary. The information contained in this document is intended as supplemental information only; it should be used in conjunction with the documentation provided for each component.

Software License Agreement

The software is provided under license agreements and may contain third-party software under separate third-party licensing. Refer to the license files provided with the software for specific details.

If You Need Help

Technical support for all Cornelis products is available 24 hours a day, 365 days a year.

For additional details:

New in This Release

The following features are new in this release:

  • Maintenance Updates

Firmware Components

This release contains the firmware components listed in the following table.

Firmware Components

Description

File Name

Version

BMC Firmware

CN5000.BMCFirmware-12.1.0.0.74.pkg

12.1.0



System Requirements

This section lists the supported hardware.

Supported Hardware

The following tables list the hardware supported in this release.

Switch Products

Hardware

Description

CN5000 Switch

CN5000 Switch, 48-Port, CN5SWE48G2AF

240/277 VAC in, Dual Power Supply, Air-Cooled, Fan-to-Port

CN5000 Switch, 48-Port, CN5SWE48G2AP

240/277 VAC in, Dual Power Supply, Air-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48G2WF

240/277 VAC in, Dual Power Supply, Liquid-Cooled, Fan-to-Port

CN5000 Switch, 48-Port, CN5SWE48G2WP

240/277 VAC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48D2AP

48 VDC in, Dual Power Supply, Air-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48D2WP

48 VDC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan

CN5000 Director Class Switch and Components

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAB

240/277 VAC in, Air-Cooled, Base Chassis

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAC

240/277 VAC in, Air-Cooled, FRU Chassis

CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48A

48-Port, Air-Cooled

CN5000 Director Class Switch, Spine Module, CN5SWDSP01A

Air-Cooled

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWB

240/277 VAC in, Liquid-Cooled, Base Chassis

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWC

240/277 VAC in, Liquid-Cooled, FRU Chassis

CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48W

48-Port, Liquid-Cooled

CN5000 Director Class Switch, Spine Module, CN5SWDSP01W

Liquid-Cooled



Installation Requirements

Refer to the CN5000 Maintenance and Troubleshooting Guide for instructions to update the switch firmware.

Best Practices
  • To obtain the most recent functional and security updates, Cornelis recommends that you download and install the latest versions of the CN5000 Omni-Path software and firmware. Software and Documentation are found in the Cornelis Customer Center.

  • To ensure optimal performance in your CN5000 fabric, it is important to review the Cornelis performance tuning recommendations in the CN5000 Performance Tuning Guide.

Issues

This section lists the resolved and open issues.

Resolved Issues

The following table lists issues that are resolved in this release.

Issues Resolved in this Release

ID

Description

Resolved in Release

STL-75426

When custom users are added to the DCS, they are not synchronized between the two Management Modules (MM).

12.1.0

STL-75420

When updating the BMC firmware on the DCS, if the selected firmware image number (1 or 2) of a board is not set to same firmware image number as the primary MM, then the firmware update will not propagate to the out of sync board/boards.

12.1.0

STL-75258

When running the switch CLI capture state take command, a message states to wait for 5 minutes for the statedump to complete. However, the statedump may take longer than 5 minutes.

12.1.0

STL-75223

The LED colors and statuses reported by switch CLI hardware led command do not match the physical LEDs.

12.1.0

STL-74875

When executing network chassis gateway <IP Address>, the command will set the chassis IP instead of a gateway. The chassis does not support setting a gateway.

12.1.0

STL-74845

The switch CLI hardware led command does not show the state of the LEDs in a DCS.

12.1.0

STL-74450

Setting the NTP server on the primary Management Module (MM) does not propagate to the secondary MM.

12.1.0

STL-74386

When a new user is created within the admin group and you switch to the new user, they will not have access to the admin commands.

12.1.0

STL-74368

Aborting while creating a new user will create the user, but the user will not be accessible.

12.1.0

STL-74363

The beacon command does not cause the beacon LED to flash.

12.1.0

STL-73895

The capture state command fails with with Error running SCP command.

12.1.0

STL-73885

The port show command does not display subdivided child ports.

12.1.0

STL-73477

The capture port command fails with an Invalid port name error.

12.1.0

STL-73431

Pressing and holding Ctrl+C during command execution can cause the CLI to become non-responsive.

12.1.0

STL-73400

Rebooting the switch in a non-interactive SSH session may result in the following error:

EOFError: Ran out of input
Lost Communication with server

12.1.0

STL-73355

In the port show switch command, TX Packet Count and RX Packet Count display inaccurate values.

12.1.0

STL-73029

BEL DC power supplies VOUT_MODE command returns incorrect results.

12.1.0

STL-72795

Commands showing the QSFP max temperature will show an invalid number for the QSFP max temperature if no cables are installed.

12.1.0

STL-72706

CLI hang occurs if CTRL+C is used during password entry for SCP for firmware update.

12.1.0

STL-72570

IPv4 addresses display incorrectly when using the opasmaquery command.

12.1.0

STL-72273

Mistyped commands may cause the CLI to stop responding.

12.1.0

STL-72226

Switch CLI log command may take 6-8 minutes to complete.

12.1.0



Open Issues

The following table lists the open issues for this release.

Open Issues

ID

Description

Workaround

STL-75396

If the Real-Time Clock (RTC) has lost power, then the Network Time Protocol (NTP) cannot be set.

Contact support@cornelis.com.

STL-75381

Prior to a reboot, the secondary Management Module (MM) may not reflect the current status of the image that should be booted after a BMC update.

Prior to a reboot of the secondary MM, select the image to be booted using firmware select bmc <1 or 2>.

STL-75248

When rebooting individual cards using the switch CLI reboot command, that CLI session can no longer connect to the chassis hardware.

Open a new CLI session.

STL-74852

The switch CLI watch command does not operate properly for DCS spine and leaf cards.

Do not use the watch command.

STL-73311

If a server's SSH host identification (host key) is changed, such as by reinstalling the OS or routing a hostname to a different server, switch maintenance tasks run from the switch that use file transfers (such as firmware udpate and capture state copy) can fail with an error message about SSH usage.

Use scp for file transfers from the server into the switch.

  • For firmware update, copy the *.pkg to /tmp/pldm-images on the switch.

  • For state dumps, scp from the switch's state dump files located in /usr/local/asicdump/.

STL-72221

Switch in-band management including configuring an IPoIB interface is not available. 

Use the switch's Ethernet or serial connections for switch management.



Product Limitations

This release has the following product limitations:

  • The OpenBMC Web User Interface is not supported.

Download PDF

Preface

This document provides an overview of the changes introduced in this release. References to more detailed information are provided where necessary. The information contained in this document is intended as supplemental information only; it should be used in conjunction with the documentation provided for each component.

Software License Agreement

The software is provided under license agreements and may contain third-party software under separate third-party licensing. Refer to the license files provided with the software for specific details.

If You Need Help

Technical support for all Cornelis products is available 24 hours a day, 365 days a year.

For additional details:

New in This Release

The following features are new in this release:

Firmware Components

This release contains the firmware components listed in the following table.

Firmware Components

Description

File Name

Version

BMC Firmware

CN5000.BMCFirmware-12.0.2.0.7.pkg

12.0.2



System Requirements

This section lists the supported hardware.

Supported Hardware

The following tables list the hardware supported in this release.

Switch Products

Hardware

Description

CN5000 Switch, 48-Port, CN5SWE48G2AF

240/277 VAC in, Dual Power Supply, Air-Cooled, Fan-to-Port

CN5000 Switch, 48-Port, CN5SWE48G2AP

240/277 VAC in, Dual Power Supply, Air-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48G2WF

240/277 VAC in, Dual Power Supply, Liquid-Cooled, Fan-to-Port

CN5000 Switch, 48-Port, CN5SWE48G2WP

240/277 VAC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48D2AP

48 VDC in, Dual Power Supply, Air-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48D2WP

48 VDC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan



Installation Requirements

Refer to the CN5000 Maintenance and Troubleshooting Guide for instructions to update the switch firmware.

Best Practices
  • To obtain the most recent functional and security updates, Cornelis recommends that you download and install the latest versions of the CN5000 Omni-Path software and firmware. Software and Documentation are found in the Cornelis Customer Center.

  • To ensure optimal performance in your CN5000 fabric, it is important to review the Cornelis performance tuning recommendations in the CN5000 Performance Tuning Guide.

Issues

This section lists the resolved and open issues.

Resolved Issues

None.

The following table lists issues that are resolved in this release.

Issues Resolved in this Release

ID

Description

Resolved in Release

STL-74386

When a new user is created within the admin group and you switch to the new user, they will not have access to the admin commands.

12.0.2

STL-73477

The capture port command fails with an Invalid port name error.

12.0.2

STL-73355

In the port show switch command, TX Packet Count and RX Packet Count display inaccurate values.

12.0.2

STL-73029

BEL DC power supplies VOUT_MODE command returns incorrect results.

12.0.2



Open Issues

The following table lists the open issues for this release.

Open Issues

ID

Description

Workaround

STL-74368

Aborting while creating a new user will create the user, but the user will not be accessible.

Delete the user and recreate as needed.

STL-73895

The capture state command fails with with Error running SCP command.

None.

STL-73885

The port show command does not display subdivided child ports.

Use the port config show command.

STL-73431

Pressing and holding Ctrl+C during command execution can cause the CLI to become non-responsive.

Press Ctrl+\ to close the session and connect again.

STL-73400

Rebooting the switch in a non-interactive SSH session may result in the following error:

EOFError: Ran out of input
Lost Communication with server

This error may be ignored. The switch will reboot successfully.

STL-73311

If a server's SSH host identification (host key) is changed, such as by reinstalling the OS or routing a hostname to a different server, switch maintenance tasks run from the switch that use file transfers (such as firmware udpate and capture state copy) can fail with an error message about SSH usage.

Use scp for file transfers from the server into the switch.

  • For firmware update, copy the *.pkg to /tmp/pldm-images on the switch.

  • For state dumps, scp from the switch's state dump files located in /usr/local/asicdump/.

STL-73121

The OpenBMC Web User Interface is not supported. 

No workaround.

STL-72795

Commands showing the QSFP max temperature will show an invalid number for the QSFP max temperature if no cables are installed.

No workaround.

STL-72706

CLI hang occurs if CTRL+C is used during password entry for SCP for firmware update.

To recover, perform one of the following:

  • Close the terminal session.

  • Press the SSH escape sequence

STL-72570

IPv4 addresses display incorrectly when using the opasmaquery command.

Use the switch CLI network command to find the switch IPv4 and IPv6 addresses.

STL-72273

Mistyped commands may cause the CLI to stop responding.

Recover by starting a new ssh session.

STL-72226

Switch CLI log command may take 6-8 minutes to complete.

No workaround.

STL-72221

Switch in-band management including configuring an IPoIB interface is not available. 

Use the switch's Ethernet or serial connections for switch management.



Product Limitations

None.

Download PDF

Preface

This document provides an overview of the changes introduced in this release. References to more detailed information are provided where necessary. The information contained in this document is intended as supplemental information only; it should be used in conjunction with the documentation provided for each component.

Software License Agreement

The software is provided under license agreements and may contain third-party software under separate third-party licensing. Refer to the license files provided with the software for specific details.

If You Need Help

Technical support for all Cornelis products is available 24 hours a day, 365 days a year.

For additional details:

New in This Release

The following features are new in this release:

Firmware Components

This release contains the firmware components listed in the following table.

Firmware Components

Description

File Name

Version

BMC Firmware

CN5000.BMC-12.0.1.0.1.pkg

12.0.1



System Requirements

This section lists the supported hardware.

Supported Hardware

The following tables list the hardware supported in this release.

Switch Products

Hardware

Description

CN5000 Switch, 48-Port, CN5SWE48G2AF

240/277 VAC in, Dual Power Supply, Air-Cooled, Fan-to-Port

CN5000 Switch, 48-Port, CN5SWE48G2AP

240/277 VAC in, Dual Power Supply, Air-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48G2WF

240/277 VAC in, Dual Power Supply, Liquid-Cooled, Fan-to-Port

CN5000 Switch, 48-Port, CN5SWE48G2WP

240/277 VAC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48D2AP

48 VDC in, Dual Power Supply, Air-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48D2WP

48 VDC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan



Installation Requirements

Refer to the CN5000 Maintenance and Troubleshooting Guide for instructions to update the switch firmware.

Best Practices
  • To obtain the most recent functional and security updates, Cornelis recommends that you download and install the latest versions of the CN5000 Omni-Path software and firmware. Software and Documentation are found in the Cornelis Customer Center.

  • To ensure optimal performance in your CN5000 fabric, it is important to review the Cornelis performance tuning recommendations in the CN5000 Performance Tuning Guide.

Issues

This section lists the resolved and open issues.

Resolved Issues

None.

Open Issues

The following table lists the open issues for this release.

Open Issues

ID

Description

Workaround

STL-74386

When a new user is created within the admin group and you switch to the new user, they will not have access to the admin commands.

None.

STL-74368

Aborting while creating a new user will create the user, but the user will not be accessible.

Delete the user and recreate as needed.

STL-73895

The capture state command fails with with Error running SCP command.

None.

STL-73885

The port show command does not display subdivided child ports.

Use the port config show command.

STL-73477

The capture port command fails with an Invalid port name error.

Use the following commands instead:

  • port show

  • port show config

STL-73431

Pressing and holding Ctrl+C during command execution can cause the CLI to become non-responsive.

Press Ctrl+\ to close the session and connect again.

STL-73400

Rebooting the switch in a non-interactive SSH session may result in the following error:

EOFError: Ran out of input
Lost Communication with server

This error may be ignored. The switch will reboot successfully.

STL-73355

In the port show switch command, TX Packet Count and RX Packet Count display inaccurate values.

Use opapmaquery to query Xmit Pkts and Rcv Pkts counters.

STL-73311

If a server's SSH host identification (host key) is changed, such as by reinstalling the OS or routing a hostname to a different server, switch maintenance tasks run from the switch that use file transfers (such as firmware udpate and capture state copy) can fail with an error message about SSH usage.

Use scp for file transfers from the server into the switch.

  • For firmware update, copy the *.pkg to /tmp/pldm-images on the switch.

  • For state dumps, scp from the switch's state dump files located in /usr/local/asicdump/.

STL-73121

The OpenBMC Web User Interface is not supported. 

No workaround.

STL-72795

Commands showing the QSFP max temperature will show an invalid number for the QSFP max temperature if no cables are installed.

No workaround.

STL-72706

CLI hang occurs if CTRL+C is used during password entry for SCP for firmware update.

To recover, perform one of the following:

  • Close the terminal session.

  • Press the SSH escape sequence

STL-72570

IPv4 addresses display incorrectly when using the opasmaquery command.

Use the switch CLI network command to find the switch IPv4 and IPv6 addresses.

STL-72273

Mistyped commands may cause the CLI to stop responding.

Recover by starting a new ssh session.

STL-72226

Switch CLI log command may take 6-8 minutes to complete.

No workaround.

STL-72221

Switch in-band management including configuring an IPoIB interface is not available. 

Use the switch's Ethernet or serial connections for switch management.



Product Limitations

None.