12.1.2
Preface
This document provides an overview of the changes introduced in this release. References to more detailed information are provided where necessary. The information contained in this document is intended as supplemental information only; it should be used in conjunction with the documentation provided for each component.
Software License Agreement
The software is provided under license agreements and may contain third-party software under separate third-party licensing. Refer to the license files provided with the software for specific details.
If You Need Help
Technical support for all Cornelis products is available 24 hours a day, 365 days a year.
For additional details:
Visit the Cornelis Support page at http://www.cornelisnetworks.com/support
Contact email: support@cornelisnetworks.com
New in This Release
The following features are new in this release:
Maintenance Updates
Firmware Components
This release contains the firmware components listed in the following table.
Description | File Name | Version |
|---|---|---|
BMC Firmware | CN5000.BMCFirmware-12.1.2.0.3.pkg | 12.1.2 |
System Requirements
This section lists the supported hardware.
Supported Hardware
The following tables list the hardware supported in this release.
Hardware | Description |
|---|---|
CN5000 Switch | |
CN5000 Switch, 48-Port, CN5SWE48G2AF | 240/277 VAC in, Dual Power Supply, Air-Cooled, Fan-to-Port |
CN5000 Switch, 48-Port, CN5SWE48G2AP | 240/277 VAC in, Dual Power Supply, Air-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48G2WF | 240/277 VAC in, Dual Power Supply, Liquid-Cooled, Fan-to-Port |
CN5000 Switch, 48-Port, CN5SWE48G2WP | 240/277 VAC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48D2AP | 48 VDC in, Dual Power Supply, Air-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48D2WP | 48 VDC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan |
CN5000 Director Class Switch and Components | |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAB | 240/277 VAC in, Air-Cooled, Base Chassis |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAC | 240/277 VAC in, Air-Cooled, FRU Chassis |
CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48A | 48-Port, Air-Cooled |
CN5000 Director Class Switch, Spine Module, CN5SWDSP01A | Air-Cooled |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWB | 240/277 VAC in, Liquid-Cooled, Base Chassis |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWC | 240/277 VAC in, Liquid-Cooled, FRU Chassis |
CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48W | 48-Port, Liquid-Cooled |
CN5000 Director Class Switch, Spine Module, CN5SWDSP01W | Liquid-Cooled |
Installation Requirements
Refer to the CN5000 Maintenance and Troubleshooting Guide for instructions to update the switch firmware.
Best Practices
To obtain the most recent functional and security updates, Cornelis recommends that you download and install the latest versions of the CN5000 Omni-Path software and firmware. Software and Documentation are found in the Cornelis Customer Center.
To ensure optimal performance in your CN5000 fabric, it is important to review the Cornelis performance tuning recommendations in the CN5000 Performance Tuning Guide.
Issues
This section lists the resolved and open issues.
Resolved Issues
The following table lists issues that are resolved in this release.
ID | Description | Resolved in Release |
|---|---|---|
STL-77092 | Liquid-cooled switches running firmware BMC 12.1.1.0.9 and ASIC 12_1_1_0_6 display | 12.1.1.1 |
STL-75426 | When custom users are added to the DCS, they are not synchronized between the two Management Modules (MM). | 12.1.0 |
STL-75420 | When updating the BMC firmware on the DCS, if the selected firmware image number (1 or 2) of a board is not set to same firmware image number as the primary MM, then the firmware update will not propagate to the out of sync board/boards. | 12.1.0 |
STL-75396 | If the Real-Time Clock (RTC) has lost power, then the Network Time Protocol (NTP) cannot be set. | 12.1.2 |
STL-75258 | When running the switch CLI | 12.1.0 |
STL-75248 | When rebooting individual cards using the switch CLI | 12.1.1 |
STL-75223 | The LED colors and statuses reported by switch CLI | 12.1.0 |
STL-74875 | When executing | 12.1.0 |
STL-74852 | The switch CLI | 12.1.1 |
STL-74845 | The switch CLI | 12.1.0 |
STL-74450 | Setting the NTP server on the primary Management Module (MM) does not propagate to the secondary MM. | 12.1.0 |
STL-74386 | When a new user is created within the admin group and you switch to the new user, they will not have access to the admin commands. | 12.1.0 |
STL-74368 | Aborting while creating a new user will create the user, but the user will not be accessible. | 12.1.0 |
STL-74363 | The | 12.1.0 |
STL-73895 | The | 12.1.0 |
STL-73885 | The | 12.1.0 |
STL-73477 | The | 12.1.0 |
STL-73431 | Pressing and holding | 12.1.0 |
STL-73400 | Rebooting the switch in a non-interactive SSH session may result in the following error: EOFError: Ran out of input Lost Communication with server | 12.1.0 |
STL-73355 | In the | 12.1.0 |
STL-73029 | BEL DC power supplies VOUT_MODE command returns incorrect results. | 12.1.0 |
STL-72795 | Commands showing the QSFP max temperature will show an invalid number for the QSFP max temperature if no cables are installed. | 12.1.0 |
STL-72706 | CLI hang occurs if | 12.1.0 |
STL-72570 | IPv4 addresses display incorrectly when using the | 12.1.0 |
STL-72273 | Mistyped commands may cause the CLI to stop responding. | 12.1.0 |
STL-72226 | Switch CLI | 12.1.0 |
Open Issues
The following table lists the open issues for this release.
ID | Description | Workaround |
|---|---|---|
STL-76777 | Using the | Reboot the BMC to clear the static IP. |
STL-76775 | Ports that have been disabled may be re-enabled after a reboot of the switch. | Disable the ports again after a switch reboot. |
STL-76677 | When removing SSH keys, partial matches of the comment could remove more keys than intended. | When removing an SSH key, use the entire comment of the key. |
STL-76490 STL-76486 | Port configuration changes are not consistently applied when bouncing a link. | Explicitly disable the link and then enable the link for the changes to take effect. |
STL-75381 | Prior to a reboot, the secondary Management Module (MM) may not reflect the current status of the image that should be booted after a BMC update. | Prior to a reboot of the secondary MM, select the image to be booted using |
STL-73311 | If a server's SSH host identification (host key) is changed, such as by reinstalling the OS or routing a hostname to a different server, switch maintenance tasks run from the switch that use file transfers (such as | Use
|
STL-72221 | Switch in-band management including configuring an IPoIB interface is not available. | Use the switch's Ethernet or serial connections for switch management. |
Product Limitations
This release has the following product limitations:
The OpenBMC Web User Interface is not supported.
Preface
This document provides an overview of the changes introduced in this release. References to more detailed information are provided where necessary. The information contained in this document is intended as supplemental information only; it should be used in conjunction with the documentation provided for each component.
Software License Agreement
The software is provided under license agreements and may contain third-party software under separate third-party licensing. Refer to the license files provided with the software for specific details.
If You Need Help
Technical support for all Cornelis products is available 24 hours a day, 365 days a year.
For additional details:
Visit the Cornelis Support page at http://www.cornelisnetworks.com/support
Contact email: support@cornelisnetworks.com
New in This Release
The following features are new in this release:
Maintenance Updates
Firmware Components
This release contains the firmware components listed in the following table.
Description | File Name | Version |
|---|---|---|
Firmware Update Tool (includes updateAgent) | CN5000_FW_UPDATE_Agent-12.1.2.0.1.tgz | 12.1.2 |
System Requirements
This section lists the supported hardware.
Supported Hardware
The following tables list the hardware supported in this release.
Hardware | Description |
|---|---|
CN5000 SuperNIC, CN5HFA2D5ALS | Dual Port, QSFP-DD, x16 PCIe Gen 5, Air-Cooled, Low Profile, Single |
CN5000 SuperNIC, CN5HFA1Q5ALS | Single Port, QSFP, x16 PCIe Gen 5, Air-Cooled, Low Profile, Single |
CN5000 SuperNIC, CN5HFA1Q5NLS | Single Port, QSFP, x16 PCIe Gen 5, Conduction-Cooled, Low Profile, Single |
Installation Requirements
Refer to the CN5000 Maintenance and Troubleshooting Guide for instructions to update the switch firmware.
Best Practices
To obtain the most recent functional and security updates, Cornelis recommends that you download and install the latest versions of the CN5000 Omni-Path software and firmware. Software and Documentation are found in the Cornelis Customer Center.
To ensure optimal performance in your CN5000 fabric, it is important to review the Cornelis performance tuning recommendations in the CN5000 Performance Tuning Guide.
Issues
This section lists the resolved and open issues.
Resolved Issues
The following table lists issues that are resolved in this release.
ID | Description | Resolved in Release |
|---|---|---|
STL-73440 | Running the updateAgent while the Fabric Manager is running may result in a segfault. | 12.1.2 |
STL-72556 | When updating firmware in a CN5000 SuperNIC in a management node, updateAgent times out when the FM is running at the same time. | 12.1.2 |
Open Issues
The following table lists the open issues for this release.
ID | Description | Workaround |
|---|---|---|
STL-77756 | After updating the SuperNIC firmware using updateAgent, one or more SuperNIC cards in a multi-card system may remain in a "Pending" firmware state following an AC power cycle. Additional AC power cycles do not resolve the issue. | Re-run the updateAgent firmware update on the affected SuperNIC card(s). To help ensure all cards complete the firmware update on the first attempt, fully power off the system (not just a power cycle) and wait at least one minute before powering back on, allowing all card capacitors to fully discharge. |
STL-75609 | The updateAgent tool may become stuck when downgrading SuperNIC firmware. | Use |
STL-73195 | When updating the SuperNIC firmware using
| Retry the |
STL-72988 STL-72556 | When updating firmware in a CN5000 SuperNIC in a management node, updateAgent times out when the FM is running at the same time. | Run the updateAgent with the Refer to the CN5000 Maintenance and Troubleshooting Guide, “Update the SuperNIC Firmware” for the full procedure. |
Product Limitations
None.
Preface
This document provides an overview of the changes introduced in this release. References to more detailed information are provided where necessary. The information contained in this document is intended as supplemental information only; it should be used in conjunction with the documentation provided for each component.
Software License Agreement
The software is provided under license agreements and may contain third-party software under separate third-party licensing. Refer to the license files provided with the software for specific details.
If You Need Help
Technical support for all Cornelis products is available 24 hours a day, 365 days a year.
For additional details:
Visit the Cornelis Support page at http://www.cornelisnetworks.com/support
Contact email: support@cornelisnetworks.com
Release Compatibility
This release is backward compatible with the most recent minor release version. For example, Release 12.N is backward compatible with Release 12.N-1 and Release 12.N-1.x.
New in This Release
The following features are new in this release:
Maintenance Updates
MPI and Verbs Performance Improvement
Release Items
The following software package is available for this release:
CN5000_OPXSoftware-<DISTRO>-12.1.2.0.40.tgz
Note
OS RPMs may need to be installed prior to software installation. Dependencies will be flagged during installation.
The following table lists meta package files provided for this release.
RPM Name | Description |
|---|---|
RHEL and SLES | |
cn5000_pkgs_cuda_meta-12_1_2_0-40.x86_64.rpm | CN5000 Meta Package containing all of the required CUDA RPMs |
cn5000_pkgs_non_gpu_meta-12_1_2_0-40.x86_64.rpm | CN5000 Meta Package containing all of the required RPMs |
cn5000_pkgs_rocm_meta-12_1_2_0-40.x86_64.rpm | CN5000 Meta Package containing all of the required ROCm RPMs |
Ubuntu | |
cn5000-pkgs-cuda-meta_12.1.2.0.40-amd64.deb | CN5000 Meta Package containing all of the required CUDA DEBs |
cn5000-pkgs-non-gpu-meta_12.1.2.0.40-amd64.deb | CN5000 Meta Package containing all of the required DEBs |
cn5000-pkgs-rocm-meta_12.1.2.0.40-amd64.deb | CN5000 Meta Package containing all of the required ROCm DEBs |
Refer to Appendix D, Release Package Manifest for the list of RPM and DEB files provided in this release.
System Requirements
This section lists the compatible operating systems and supported hardware.
Operating Systems
This release of the CN5000 OPX Software supports the operating systems listed in the following table.
Operating System | Base Kernel Version |
|---|---|
RHEL 9.4 | 5.14.0-427.13.1el9_4.x86_64 |
RHEL 9.5 | 5.14.0-503.11.1.el9_5.x86_64 |
RHEL 9.6 | 5.14.0-570.12.1.el9_6.x86_64 |
RHEL 9.7 | 5.14.0-611.5.1.el9_7.x86_64 |
RHEL 10.0 | 6.12.0-55.9.1.el10_0.x86_64 |
Rocky Linux 9.5 | 5.14.0-503.14.1.el9_5.x86_64 |
Rocky Linux 9.6 | 5.14.0-570.17.1el9_6.x86_64 |
Rocky Linux 9.7 | 5.14.0-611.5.1.el9_7.x86_64 |
Rocky Linux 10.0 | 6.12.0-55.12.1.el10_0.x86_64 |
SLES 15 SP7 | 6.4.0-150700.53.22.1-default |
Ubuntu 24.04 LTS | 6.8.0-90-generic |
Supported GPU Software
This release supports the GPU Software versions listed in the following table.
Note
The libfabric source rpm can be rebuilt to work with other ROCm and CUDA versions. Contact support@cornelis.com for assistance if needed.
Operating System | ROCm Version | CUDA Version |
|---|---|---|
RHEL/Rocky 9.4 | 6.2.0 | 13.1 |
RHEL/Rocky 9.5 | 6.3.0 | 13.1 |
RHEL/Rocky 9.6 | 6.4.2 | 12.9 |
RHEL/Rocky 9.7 | 7.1.1 | 13.1 |
RHEL/Rocky 10 | 7.1.1 | 13.1 |
SLES 15 SP7 | 6.4.3 | 13.0 |
Ubuntu 24.04 | 6.1.2 | 12.9 |
Supported Hardware
The following tables list the hardware supported in this release.
Hardware | Description |
|---|---|
CN5000 Switch | |
CN5000 Switch, 48-Port, CN5SWE48G2AF | 240/277 VAC in, Dual Power Supply, Air-Cooled, Fan-to-Port |
CN5000 Switch, 48-Port, CN5SWE48G2AP | 240/277 VAC in, Dual Power Supply, Air-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48G2WF | 240/277 VAC in, Dual Power Supply, Liquid-Cooled, Fan-to-Port |
CN5000 Switch, 48-Port, CN5SWE48G2WP | 240/277 VAC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48D2AP | 48 VDC in, Dual Power Supply, Air-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48D2WP | 48 VDC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan |
CN5000 Director Class Switch and Components | |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAB | 240/277 VAC in, Air-Cooled, Base Chassis |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAC | 240/277 VAC in, Air-Cooled, FRU Chassis |
CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48A | 48-Port, Air-Cooled |
CN5000 Director Class Switch, Spine Module, CN5SWDSP01A | Air-Cooled |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWB | 240/277 VAC in, Liquid-Cooled, Base Chassis |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWC | 240/277 VAC in, Liquid-Cooled, FRU Chassis |
CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48W | 48-Port, Liquid-Cooled |
CN5000 Director Class Switch, Spine Module, CN5SWDSP01W | Liquid-Cooled |
Hardware | Description |
|---|---|
CN5000 SuperNIC, CN5HFA2D5ALS | Dual Port, QSFP-DD, x16 PCIe Gen 5, Air-Cooled, Low Profile, Single |
CN5000 SuperNIC, CN5HFA1Q5ALS | Single Port, QSFP, x16 PCIe Gen 5, Air-Cooled, Low Profile, Single |
CN5000 SuperNIC, CN5HFA1Q5NLS | Single Port, QSFP, x16 PCIe Gen 5, Conduction-Cooled, Low Profile, Single |
Hardware | Description |
|---|---|
CPUs | |
4th Gen AMD EPYC Processor | Genoa Zen 4 CPU-based servers |
5th Gen AMD EPYC Processor | Turin Zen 5 CPU-based servers |
4th Generation Intel Xeon Scalable Processor | Sapphire Rapids CPU-based servers |
5th Generation Intel Xeon Scalable Processor | Emerald Rapids CPU-based servers |
GPUs | |
AMD Instinct MI Series GPU | AMD Instinct MI300X and MI200 series Graphic Processing Units |
NVIDIA GPUs | NVIDIA Tesla V100 and later |
Installation Requirements
Refer to the CN5000 Fabric Installation Guide for related software requirements and complete installation procedures.
Best Practices
To obtain the most recent functional and security updates, Cornelis recommends that you download and install the latest versions of the CN5000 Omni-Path software and firmware. Software and Documentation are found in the Cornelis Customer Center.
To ensure optimal performance in your CN5000 fabric, it is important to review the Cornelis performance tuning recommendations in the CN5000 Performance Tuning Guide.
Disable the Repository After OPX Software Installation
Required for RHEL 9.5.
After installing or updating the OPX Software, disable the repository on every node using one of the following methods:
Run the following command:
sudo dnf config-manager --set-disabled <repo>
In the repository file, change
enableto0.
Issues
This section lists the resolved and open issues.
Resolved Issues
The following table lists issues that are resolved in this release.
ID | Description | Resolved in Release |
|---|---|---|
STL-76263 | In some circumstances, rebooting a host may cause a panic. | 12.1.2 |
STL-76108 | SR-IOV Virtual Function devices on CN5000 cannot query the Subnet Administration. | 12.1.2 |
STL-75394 | On some systems running Ubuntu 24.04, the hfi1 driver may fail to start when it is unloaded and reloaded. The system log will contain a message saying | 12.1.2 |
STL-74593 | The Quantum Espresso application with Intel MPI may abort with SIGABRT when executed with a higher number of MPI ranks than available user HFI contexts and multiple endpoints per HFI context (FI_OPX_ENDPOINTS_PER_HFI_CONTEXT=2) | 12.1.2 |
STL-74230 | IPoIB interfaces on CN5000 currently do not support failover with the Channel Bonding driver in the Linux kernel. | 12.1.2 |
STL-73709 | The | 12.1.2 |
STL-73330 | Some LS-DYNA R14.1.0. benchmarks hang with Open MPI when using the OPX Provider for libfabric. | 12.1.2 |
STL-72649 | An Open MPI error may occur when using | 12.1.2 |
STL-72431 | The command | 12.1.2 |
STL-76222 | Memory overflow may occur when running MVAPICH on Ubuntu platforms. | 12.1.1 |
STL-76135 | When using SR-IOV, jobs running high processes per node (PPN) may fail on virtual machines with limited resources. | 12.1.1 |
STL-75555 | Errors can occur when installing Ubuntu meta-packages with | 12.1.1 |
STL-75331 | Using RDMA Core persistent names with settings other than KERNEL will result in RCCL segmentation faults. | 12.1.1 |
STL-70422 | RCCL hangs on AMD GPUs with opx and aws-ofi-rccl plugin. | 12.1.1 |
STL-76376 | Kernel crash may occur when hfi1 module is loaded with | 12.1.0.1 |
STL-76375 | MPI or middleware using the OPX Libfabric Provider may experience unreliable results. | 12.1.0.1 |
STL-76373 | Benign hfi1 messages relating to MCTXT interrupt in kernel logs can be ignored. | 12.1.0.1 |
STL-75066 | If IPv6 is enabled on any IPoIB interfaces, the FM sweeps constantly due to changes in multicast group membership. | 12.1.0 |
STL-74951 STL-74672 | On rare occasions, application hangs with an SDMA engine error in DMSG have been observed. | 12.1.0 |
STL-74696 | When running an NVIDIA GPU Cloud (NGC) container such as the "NVIDIA HPC-Benchmarks" package, a segmentation fault may occur. | 12.1.0 |
STL-74672 | On rare occasions, application hangs with an SDMA engine error in DMSG have been observed. | 12.1.0 |
STL-74234 | The mvapich2 packages provided with OPX Software should be ignored and not used. | 12.1.0 |
STL-74218 | IPoIB interfaces on CN5000 currently do not support failover with the Channel Bonding driver in the Linux kernel. | 12.1.0 |
STL-73861 | Hangs occur when using NVMe over Fabric. | 12.1.0 |
STL-73759 | When the FM restarts, different LIDs may get assigned to the nodes. | 12.1.0 |
STL-73267 | When running the | 12.1.0 |
STL-73245 | CN5000 Switch-Switch links do not appear in either | 12.1.0 |
STL-72864 | High CPU utilization seen for hfi1 related interrupts, potentially impacting performance. | 12.1.0 |
STL-72815 |
| 12.1.0 |
STL-72640 | In some cases the dmesg log may contain a message stating:
| 12.1.0 |
STL-72575 | TID updates under heavy load may result in an | 12.1.0 |
STL-72572 | In | 12.1.0 |
STL-72547 | Class Port Info queries are not reporting properly. | 12.1.0 |
Open Issues
The following tables list the open issues for this release.
ID | Description | Workaround |
|---|---|---|
STL-77956 | GPU applications hang with Open MPI 5.0.8 and earlier | Use Open MPI 5.0.9 or newer. |
STL-77873 | Megatron-LM training (Llama3-8B) hangs on multi-node configurations when using | Use |
STL-77578 | CableInfo errors encountered when using the | Use LID-routed packets to get cable information. |
STL-76942 | Lustre errors occur with Bulk Transfer Service (BTS) enabled (hfi1 driver parameter | When mounting Lustre, BTS should not be enabled ( |
STL-76907 | The following Lustre Error may occur: Write request failed with -14 NOTE: This is a general defect that affects all Lustre 2.17.0 stacks (refer to Lustre-Release Issue #16 | Avoid this issue by disabling hybrid IO functionality using the following command on the MGS server: lctl set_param -P llite.*.hybrid_io=0 |
STL-76435 |
Invalid Attribute or Attribute Modifier NOTE: The PMA response has a maximum payload size that limits the number of ports that can be returned in a single query. | Split the port select mask ( For example, on a 48-port switch, query ports in groups of 20 or fewer:
|
STL-76348 | Running | None. |
STL-76323 | SuperNICs may intermittently fail to enumerate on the PCIe bus or initialize after a cold boot or power cycle. In affected systems, one or more SuperNICs may be absent from the OS, preventing the node from participating in the fabric until the device is successfully detected and initialized. | Power cycle the server. |
STL-76313 | Kernel messages such as the following may be seen: CPORT request wait interrupted Dropping incoming CPORT message | Set the hfi1 module parameter |
STL-76144 | Setting the link speed policy to 100G in the opafm.xml file results in the following Fabric Manager error: Invalid Value for Link Speed Policy: 100G | Set the link speed using the Switch CLI command |
STL-76137 | Open MPI traffic fails on SR-IOV Virtual Function devices. | Use the |
STL-76131 | When using SR-IOV, the dmesg log in the VMs may occasionally show the following warning message: memcpy: detected field-spanning write | Do not run Omni-Path management tools, such as |
STL-75568 | Performance test failures may occur when running ib_send_bw and ib_read_bw with the | Do not use the |
STL-75535 | GADGET4 MPI application hangs with OPX Provider. | Contact support@cornelis.com. |
STL-75526 | After installing the OPX Software package on Ubuntu, the opafm service is enabled by default. | Manually disable the opafm service by default. |
STL-75484 | Running | To drop and reinitialize a link, use the Alternately, if |
STL-75395 | When | Disable |
STL-75362 | When using the TCP provider of libfabric, some MPI application may perform poorly or hang when launched with 1 process per core. This has been observed in benchmarks such as OSU Congestion, OSU Collectives, and IMB P2P. | For best results, users should use the OPX provider whenever available. OPX can be explicitly selected by setting the environment variable, |
STL-75322 | Upon reverting from 12.0.3 to a previous RHEL/Rocky release certain packages may not be removed. | Use the following command to remove the remaining packages: dnf remove ibacm infiniband-diags libfabric libhfi1verbs libibumad libibverbs libpsm2 librdmacm librdmacm-utils mpi-selector opa-basic-tools opa-fastfabric opa-fm opa-libopamgt rdma-core rdma-core-devel srp_daemon |
STL-75031 STL-76644 | MPI RMA benchmarks may produce an SDMA error (bad address) when using the OPX libfabric provider and environment variable FI_OPX_MIXED_NETWORK=0. | FI_OPX_MIXED_NETWORK is deprecated and should no longer be set. Contact support@cornelis.com. |
STL-74968 | Updating the Fabric Manager using DNF may not succeed even though an update is available. | Perform the following:
|
STL-74933 | Entries of the form | These messages can be ignored. |
STL-74679 | While running IPoIB in Connected mode, application hangs have been observed. | Configure IPoIB to Datagram mode and rerun the application. |
STL-74625 | When using both ports of a dual-port SuperNIC, the | Use |
STL-74504 | Occasional drops in bandwidth observed during microbenchmark testing. | Refer to the Performance Tuning Guide for platform-specific tuning. |
STL-74477 | Building opxs-kernel-updates from the src.rpm file fails with | Use an environment variable to allow the header file to be detected and used in the build: NVIDIA_DIR=$(ls -d /usr/src/nvidia-* | head -1)
ln -s ${NVIDIA_DIR}/nvidia /usr/src/kernels/5.14.0-503.14.1.el9_5.x86_64/include/nvidiaNote that the exact directory required for the symbolic link will depend on your kernel version. |
STL-74025 | When using IPoIB on CN5000, SuperNICs do not change MTU or join MC groups automatically. | Use the |
STL-73928 | HFI links bounce and the SM reports mapping warnings following the second FM restart. | No Workaround. Links that bounce recover and the fabric stabilizes. |
STL-73738 | Reloading the ipoib kernel module without also reloading the hfi1 module may cause FM errors. | To avoid this, always reload the hfi1 module along with the ipoib module. |
STL-73716 | The | Ignore the congestion flag. |
STL-73714 | Performing an | Counter values in this scenario should be ignored. |
STL-73713 | In a fabric with no data traffic, the Xmit Time Congestion port counter will increment. | No workaround. |
STL-73669 | Executing | The message may be ignored. |
STL-73531 | Configuring more than two data VLs is not currently supported. Doing so may lead to incorrect mappings of SC to VL. | Limit the number of configured data VLs to two. |
STL-73215 | When running | Use |
STL-73160 | The comments in the Adaptive Routing section of the opafm.xml file do not explain which settings are required for MGAR or for FGAR. | Currently the only field related to FGAR is
All other fields are related to legacy MGAR and will be ignored if |
STL-73140 | The following CN5000 commands do not work as expected:
| Note the following:
|
STL-72673 | OS-release file captured by opacapture is empty. | Use |
STL-72583 | In some cases the dmesg log may contain a message stating:
| This is cosmetic and will not affect functionality. |
STL-72573 | Hangs and errors have been seen in the OSU alltoall collective test when using the OPX Provider to libfabric with ROCm. | No workaround. |
STL-72541 | Running the | These errors can be ignored. |
STL-72536 STL-72537 | CableInfo errors encountered when using the | Cable information reporting not currently supported. |
STL-72526 | The Fabric Manager system log port numbering is different from Switch CLI command port numbering. | For details, contact support@cornelis.com for technical advisory TA0061. |
STL-72523 | Errors occur on RHEL 9.5 after installation of meta package. | Refer to Disable the Repository After OPX Software Installation. |
STL-72420 | On some versions of RHEL 9.x, there is a known failure (rdmavt driver deadlock.) recorded in https://issues.redhat.com/browse/RHEL-83851. NOTE: Cornelis has not replicated this problem but it is possible that customers may be affected. | No workaround. |
STL-72205 | FI_OPX_HFI_SELECT=[] does not correctly map to the available adapter in the case in which other adapters in the system have been disabled. | Unload and reload the driver. |
STL-72160 | After uninstalling the meta packages with a package manager, several Cornelis Networks packages remain. | Refer to the CN5000 Maintenance and Troubleshooting Guide, “Remove OPX Software from a Host” for removal of the remaining packages. |
STL-71364 STL-72423 | Some legacy Omni-Path host utilities have been deprecated for CN5000 but are still supported for OPA100. | For a list of commands supported for CN5000, refer to the Man Pages or CN5000 Commands Guide. |
STL-67178 | After boot, the OPX Software hfi1-NVIDIA support is not available. | Review boot configuration to ensure that nvidia-driver will be available when hfi1 is loaded. |
Product Limitations
This release has the following limitations:
If you plan to deploy in a hybrid fabric with OPA100 and CN5000 interoperating together, contact support@cornelis.com for guidance before deploying this release.
Bulk Transfer Service is not available on port 1 of dual port SuperNIC cards.
When running MVAPICH3 with the OPX provider of libfabric, a
*** buffer overflow detected ***error may cause the job to terminate. This issue has been observed when running with a high number of processes, particularly when using 1 process per core (that is, the maximum number of processes the system can support). A workaround is to set the environment variableMV2_ENABLE_AFFINITY=0to disable CPU affinity.Queries to single port adapters will reflect that there are two ports with the first port always showing as offline.
Running of MPI jobs across both CN5000 and OPA100 components in hybrid fabrics (fabrics where CN5000 and OPA100 are connected) is not presently supported.
In the opafm.xml file, the default HFI port for fm0 must be set to "2" for proper operation:
<Name>fm0</Name> <Hfi>1</Hfi> <Port>2</Port>Non-default
MinShareVLMemandDedicatedVLMemvalues are not supported. Only use default values.FM Failover is presently not supported. Use a single Fabric Manager.
NVMe over Fabric is currently not supported.
Some distros versions may ship with ib_qib driver enabled. This driver is incompatible with the CN5000 OPX Software and may result in errors such as
disagrees about version of symbolin logs. Setblacklist ib_qib.During link bring up on a mixed OPA100/CN5000 fabric the FM log may show "Mismatch/Unable to set SCVL_t Map" warnings and link bounces may be observed as the fabric comes up. These messages and link bounces are expected on mixed fabrics and do not indicate a fault.
Enabling vFabrics with QoS results in Neighbor Mismatch/Unable to set SCVL_nt Map and Failed to init SL Maps in the log, and port bounces. There is no workaround. Port bounces are part of the standard recovery mechanism. These messages should only occur once and only when there is a change in the SCVL maps.
opainfo displays a single port adapter as a dual port adapter. No workaround. This is informational.
Ubuntu server fails to boot with more than one CN5000 SuperNIC installed. Ubuntu platforms cannot host multiple SuperNICs.
Bulk Transfer Service (BTS, bulksvc) is not supported on GPU platforms.
MVAPICH-Plus 4.1 for GPU is not supported.
The sph_exa application in SpecHPC hangs when using Open MPI. Set the following when running Open MPI:
-mca topo ^treematch
Preface
This document provides an overview of the changes introduced in this release. References to more detailed information are provided where necessary. The information contained in this document is intended as supplemental information only; it should be used in conjunction with the documentation provided for each component.
Software License Agreement
The software is provided under license agreements and may contain third-party software under separate third-party licensing. Refer to the license files provided with the software for specific details.
If You Need Help
Technical support for all Cornelis products is available 24 hours a day, 365 days a year.
For additional details:
Visit the Cornelis Support page at http://www.cornelisnetworks.com/support
Contact email: support@cornelisnetworks.com
New in This Release
The following features are new in this release:
Single Root I/O Virtualization (SR-IOV)
Maintenance Updates
Firmware Components
This release contains the firmware components listed in the following table.
Description | File Name | Version |
|---|---|---|
SuperNIC Firmware (includes UEFI 12.1.0.9.0) | CN5000.SuperNICFirmware-12.1.2.0.8-V1.pkg | 12.1.2 |
System Requirements
This section lists the supported hardware.
Supported Hardware
The following tables list the hardware supported in this release.
Hardware | Description |
|---|---|
CN5000 SuperNIC, CN5HFA2D5ALS | Dual Port, QSFP-DD, x16 PCIe Gen 5, Air-Cooled, Low Profile, Single |
CN5000 SuperNIC, CN5HFA1Q5ALS | Single Port, QSFP, x16 PCIe Gen 5, Air-Cooled, Low Profile, Single |
CN5000 SuperNIC, CN5HFA1Q5NLS | Single Port, QSFP, x16 PCIe Gen 5, Conduction-Cooled, Low Profile, Single |
Installation Requirements
Refer to the CN5000 Maintenance and Troubleshooting Guide for instructions to update the switch firmware.
Best Practices
To obtain the most recent functional and security updates, Cornelis recommends that you download and install the latest versions of the CN5000 Omni-Path software and firmware. Software and Documentation are found in the Cornelis Customer Center.
To ensure optimal performance in your CN5000 fabric, it is important to review the Cornelis performance tuning recommendations in the CN5000 Performance Tuning Guide.
Issues
This section lists the resolved and open issues.
Resolved Issues
The following table lists issues that are resolved in this release.
ID | Description | Resolved in Release |
|---|---|---|
STL-75884 | PXE boot fails after changing the default Fabric Manager SubnetPrefix. | 12.1.2 |
STL-75486 | In rare cases, the driver may encounter an error as it loads. You will see errors in the dmesg log saying | 12.1.2 |
STL-73440 | Running the updateAgent while the Fabric Manager is running may result in a segfault. | 12.1.2 |
STL-73709 | The | 12.1.2 |
STL-73153 | The SuperNIC firmware version is currently displayed differently in different places, such as the system log versus the updateAgent. | 12.1.2 |
STL-75192 | In some rare cases, the host system may hang on a warm reboot. | 12.1.1 |
STL-74377 | In rare cases, nodes may drop from fabric with unreachable CPORT when attempting to delete or reset an IPoIB interface. | 12.1.0 |
STL-73920 | System Image GUID is the same on all SuperNICs. | 12.1.0 |
STL-73153 | The SuperNIC firmware version is currently displayed differently in different places, such as the system log versus the updateAgent. | 12.1.0 |
STL-72796 | iperf2 may occasionally hang with an SDMA status error. | 12.1.0 |
STL-72644 | While using a QSFP cable, you may see warnings in host logs regarding | 12.1.0 |
STL-72640 | In some cases the dmesg log may contain a message stating:
| 12.1.0 |
STL-72360 | After IMB-RMA Uniband operation, occasional tasks may freeze. | 12.1.0 |
Open Issues
The following table lists the open issues for this release.
ID | Description | Workaround |
|---|---|---|
STL-77756 | After updating the SuperNIC firmware using updateAgent, one or more SuperNIC cards in a multi-card system may remain in a "Pending" firmware state following an AC power cycle. Additional AC power cycles do not resolve the issue. | Re-run the updateAgent firmware update on the affected SuperNIC card(s). To help ensure all cards complete the firmware update on the first attempt, fully power off the system (not just a power cycle) and wait at least one minute before powering back on, allowing all card capacitors to fully discharge. |
STL-76776 | Network connectivity may fail after hot-swapping cables of different types on the SuperNIC. | Reboot the host to detect the new cables. |
STL-76323 | SuperNICs may intermittently fail to enumerate on the PCIe bus or initialize after a cold boot or power cycle. In affected systems, one or more SuperNICs may be absent from the OS, preventing the node from participating in the fabric until the device is successfully detected and initialized. | Power cycle the server. |
STL-75609 | The updateAgent tool may become stuck when downgrading SuperNIC firmware. | Use |
STL-74502 | When updating SuperNIC firmware with multiple SuperNIC adapters in a server, some cards may fail to properly update. | Disable the port on the failed SuperNIC cards using |
STL-73738 | Reloading the ipoib kernel module without also reloading the hfi1 module may cause FM errors. | To avoid this, always reload the hfi1 module along with the ipoib module. |
STL-73195 | When updating the SuperNIC firmware using
| Retry the |
STL-73088 | On some dual-port devices, inbound IPoIB traffic may fail after a system reboot, or after restarting the FM and IPoIB interfaces on the FM node. | Ping out from the unreachable interface, and IP traffic will resume. |
STL-72988 | When updating firmware in a CN5000 SuperNIC in a management node, updateAgent times out when the FM is running at the same time. | Run the updateAgent with the Refer to the CN5000 Maintenance and Troubleshooting Guide, “Update the SuperNIC Firmware” for the full procedure. |
STL-72817 | When reading hfi1 port counters from sysfs, you will receive an | This message can be ignored. |
STL-72598 | In some cases, when unloading hfi1 or ib_ipoib, the dmesg log may display an error stating:
| This message can be safely ignored. |
STL-72583 | In some cases the dmesg log may contain a message stating:
| This is cosmetic and will not affect functionality. |
STL-71647 | On rare occasions, the link may come up at a width less than 4X. | Bounce the link. |
Product Limitations
This release has the following product limitations:
lspci does not enumerate the CN5000 SuperNIC with ASPM enabled, causing the BIOS screen on Intel D50DNP platforms to lock up. Disable ASPM in the BIOS.
Bulk Transfer Service is not available on port 1 of dual port SuperNIC cards.
SuperNICs received from Cornelis with firmware version prior to 12.0.2.0.6 do not include UEFI (Option ROM). Contact Cornelis Customer Support for firmware and update procedures.
Update agent fails to update the SuperNIC Firmware when the OPX Software version is 12.0.2 or newer and SuperNIC Firmware is version is 12.0.1.
To work around this limitation, reduce OPX Software version to 12.0.1, update the SuperNIC Firmware to version 12.0.2, then reinstall the 12.0.2 or newer OPX Software.
CN5000 SuperNIC enumerates at x4 PCIe width on some platforms if the width is not forced to x16 in the BIOS. Configure the BIOS to enforce PCIe x16 width.
Preface
This document provides an overview of the changes introduced in this release. References to more detailed information are provided where necessary. The information contained in this document is intended as supplemental information only; it should be used in conjunction with the documentation provided for each component.
Software License Agreement
The software is provided under license agreements and may contain third-party software under separate third-party licensing. Refer to the license files provided with the software for specific details.
If You Need Help
Technical support for all Cornelis products is available 24 hours a day, 365 days a year.
For additional details:
Visit the Cornelis Support page at http://www.cornelisnetworks.com/support
Contact email: support@cornelisnetworks.com
New in This Release
The following features are new in this release:
Maintenance Updates
Firmware Components
This release contains the firmware components listed in the following table.
Description | File Name | Version |
|---|---|---|
Switch Firmware | CN5000.SwitchFirmware-12.1.2.0.3-V1.pkg | 12.1.2 |
System Requirements
This section lists the supported hardware.
Supported Hardware
The following tables list the hardware supported in this release.
Hardware | Description |
|---|---|
CN5000 Switch | |
CN5000 Switch, 48-Port, CN5SWE48G2AF | 240/277 VAC in, Dual Power Supply, Air-Cooled, Fan-to-Port |
CN5000 Switch, 48-Port, CN5SWE48G2AP | 240/277 VAC in, Dual Power Supply, Air-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48G2WF | 240/277 VAC in, Dual Power Supply, Liquid-Cooled, Fan-to-Port |
CN5000 Switch, 48-Port, CN5SWE48G2WP | 240/277 VAC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48D2AP | 48 VDC in, Dual Power Supply, Air-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48D2WP | 48 VDC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan |
CN5000 Director Class Switch and Components | |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAB | 240/277 VAC in, Air-Cooled, Base Chassis |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAC | 240/277 VAC in, Air-Cooled, FRU Chassis |
CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48A | 48-Port, Air-Cooled |
CN5000 Director Class Switch, Spine Module, CN5SWDSP01A | Air-Cooled |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWB | 240/277 VAC in, Liquid-Cooled, Base Chassis |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWC | 240/277 VAC in, Liquid-Cooled, FRU Chassis |
CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48W | 48-Port, Liquid-Cooled |
CN5000 Director Class Switch, Spine Module, CN5SWDSP01W | Liquid-Cooled |
Installation Requirements
Refer to the CN5000 Maintenance and Troubleshooting Guide for instructions to update the switch firmware.
Best Practices
To obtain the most recent functional and security updates, Cornelis recommends that you download and install the latest versions of the CN5000 Omni-Path software and firmware. Software and Documentation are found in the Cornelis Customer Center.
To ensure optimal performance in your CN5000 fabric, it is important to review the Cornelis performance tuning recommendations in the CN5000 Performance Tuning Guide.
Issues
This section lists the resolved and open issues.
Resolved Issues
The following table lists the resolved issues for this release.
ID | Description | Resolved in Release |
|---|---|---|
STL-75508 | When using the node description to query, the name has a trailing space. | 12.1.0 |
STL-73399 | After rebooting the switch ASIC, port commands may show invalid information until the switch ASIC has completed initialization. | 12.1.0 |
STL-73029 | BEL DC power supplies VOUT_MODE command returns incorrect results. | 12.1.0 |
Open Issues
The following table lists the open issues for this release.
ID | Description | Workaround |
|---|---|---|
STL-74370 | ASIC firmware update may fail with the following message: Error during firmware update Not that this message is seen when checking the status using the | Retry the ASIC firmware update. |
STL-73361 | On rare occasions, links connecting a CN5000 switch to an OPA100 adapter may unexpectedly bounce. | No action required, the link will self recover. |
STL-72526 | The Fabric Manager system log port numbering is different from Switch CLI command port numbering. | For details, contact support@cornelis.com for technical advisory TA0061. |
STL-71647 | On rare occasions, the link may come up at a width less than 4X. | Bounce the link. |
Product Limitations
None.