12.1.1.0 Release Notes

Download PDF

Preface

This document provides an overview of the changes introduced in this release. References to more detailed information are provided where necessary. The information contained in this document is intended as supplemental information only; it should be used in conjunction with the documentation provided for each component.

Software License Agreement

The software is provided under license agreements and may contain third-party software under separate third-party licensing. Refer to the license files provided with the software for specific details.

If You Need Help

Technical support for all Cornelis products is available 24 hours a day, 365 days a year.

For additional details:

New in This Release

The following features are new in this release:

  • Maintenance Updates

Firmware Components

This release contains the firmware components listed in the following table.

Firmware Components

Description

File Name

Version

BMC Firmware

CN5000.BMCFirmware-12.1.1.0.9.pkg

12.1.1.0



System Requirements

This section lists the supported hardware.

Supported Hardware

The following tables list the hardware supported in this release.

Switch Products

Hardware

Description

CN5000 Switch

CN5000 Switch, 48-Port, CN5SWE48G2AF

240/277 VAC in, Dual Power Supply, Air-Cooled, Fan-to-Port

CN5000 Switch, 48-Port, CN5SWE48G2AP

240/277 VAC in, Dual Power Supply, Air-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48G2WF

240/277 VAC in, Dual Power Supply, Liquid-Cooled, Fan-to-Port

CN5000 Switch, 48-Port, CN5SWE48G2WP

240/277 VAC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48D2AP

48 VDC in, Dual Power Supply, Air-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48D2WP

48 VDC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan

CN5000 Director Class Switch and Components

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAB

240/277 VAC in, Air-Cooled, Base Chassis

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAC

240/277 VAC in, Air-Cooled, FRU Chassis

CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48A

48-Port, Air-Cooled

CN5000 Director Class Switch, Spine Module, CN5SWDSP01A

Air-Cooled

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWB

240/277 VAC in, Liquid-Cooled, Base Chassis

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWC

240/277 VAC in, Liquid-Cooled, FRU Chassis

CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48W

48-Port, Liquid-Cooled

CN5000 Director Class Switch, Spine Module, CN5SWDSP01W

Liquid-Cooled



Installation Requirements

Refer to the CN5000 Maintenance and Troubleshooting Guide for instructions to update the switch firmware.

Best Practices
  • To obtain the most recent functional and security updates, Cornelis recommends that you download and install the latest versions of the CN5000 Omni-Path software and firmware. Software and Documentation are found in the Cornelis Customer Center.

  • To ensure optimal performance in your CN5000 fabric, it is important to review the Cornelis performance tuning recommendations in the CN5000 Performance Tuning Guide.

Issues

This section lists the resolved and open issues.

Resolved Issues

The following table lists issues that are resolved in this release.

Issues Resolved in this Release

ID

Description

Resolved in Release

STL-75426

When custom users are added to the DCS, they are not synchronized between the two Management Modules (MM).

12.1.0

STL-75420

When updating the BMC firmware on the DCS, if the selected firmware image number (1 or 2) of a board is not set to same firmware image number as the primary MM, then the firmware update will not propagate to the out of sync board/boards.

12.1.0

STL-75258

When running the switch CLI capture state take command, a message states to wait for 5 minutes for the statedump to complete. However, the statedump may take longer than 5 minutes.

12.1.0

STL-75248

When rebooting individual cards using the switch CLI reboot command, that CLI session can no longer connect to the chassis hardware.

12.1.1

STL-75223

The LED colors and statuses reported by switch CLI hardware led command do not match the physical LEDs.

12.1.0

STL-74875

When executing network chassis gateway <IP Address>, the command will set the chassis IP instead of a gateway. The chassis does not support setting a gateway.

12.1.0

STL-74852

The switch CLI watch command does not operate properly for DCS spine and leaf cards.

12.1.1

STL-74845

The switch CLI hardware led command does not show the state of the LEDs in a DCS.

12.1.0

STL-74450

Setting the NTP server on the primary Management Module (MM) does not propagate to the secondary MM.

12.1.0

STL-74386

When a new user is created within the admin group and you switch to the new user, they will not have access to the admin commands.

12.1.0

STL-74368

Aborting while creating a new user will create the user, but the user will not be accessible.

12.1.0

STL-74363

The beacon command does not cause the beacon LED to flash.

12.1.0

STL-73895

The capture state command fails with with Error running SCP command.

12.1.0

STL-73885

The port show command does not display subdivided child ports.

12.1.0

STL-73477

The capture port command fails with an Invalid port name error.

12.1.0

STL-73431

Pressing and holding Ctrl+C during command execution can cause the CLI to become non-responsive.

12.1.0

STL-73400

Rebooting the switch in a non-interactive SSH session may result in the following error:

EOFError: Ran out of input
Lost Communication with server

12.1.0

STL-73355

In the port show switch command, TX Packet Count and RX Packet Count display inaccurate values.

12.1.0

STL-73029

BEL DC power supplies VOUT_MODE command returns incorrect results.

12.1.0

STL-72795

Commands showing the QSFP max temperature will show an invalid number for the QSFP max temperature if no cables are installed.

12.1.0

STL-72706

CLI hang occurs if CTRL+C is used during password entry for SCP for firmware update.

12.1.0

STL-72570

IPv4 addresses display incorrectly when using the opasmaquery command.

12.1.0

STL-72273

Mistyped commands may cause the CLI to stop responding.

12.1.0

STL-72226

Switch CLI log command may take 6-8 minutes to complete.

12.1.0



Open Issues

The following table lists the open issues for this release.

Open Issues

ID

Description

Workaround

STL-76777

Using the network ip del command on a static IP address does not work.

Reboot the BMC to clear the static IP.

STL-76775

Ports that have been disabled may be re-enabled after a reboot of the switch.

Disable the ports again after a switch reboot.

STL-76677

When removing SSH keys, partial matches of the comment could remove more keys than intended.

When removing an SSH key, use the entire comment of the key.

STL-76490

Port configuration changes are not consistently applied when bouncing a link.

Explicitly disable the link and then enable the link for the changes to take effect.

STL-76486

When making port configuration changes on a DCS, bouncing the link alone does not apply the new configuration.

Explicitly disable the link and then enable the link for the changes to take effect.

STL-75396

If the Real-Time Clock (RTC) has lost power, then the Network Time Protocol (NTP) cannot be set.

Contact support@cornelis.com.

STL-75381

Prior to a reboot, the secondary Management Module (MM) may not reflect the current status of the image that should be booted after a BMC update.

Prior to a reboot of the secondary MM, select the image to be booted using firmware select bmc <1 or 2>.

STL-73311

If a server's SSH host identification (host key) is changed, such as by reinstalling the OS or routing a hostname to a different server, switch maintenance tasks run from the switch that use file transfers (such as firmware udpate and capture state copy) can fail with an error message about SSH usage.

Use scp for file transfers from the server into the switch.

  • For firmware update, copy the *.pkg to /tmp/pldm-images on the switch.

  • For state dumps, scp from the switch's state dump files located in /usr/local/asicdump/.

STL-72221

Switch in-band management including configuring an IPoIB interface is not available. 

Use the switch's Ethernet or serial connections for switch management.



Product Limitations

This release has the following product limitations:

  • The OpenBMC Web User Interface is not supported.

Download PDF

Preface

This document provides an overview of the changes introduced in this release. References to more detailed information are provided where necessary. The information contained in this document is intended as supplemental information only; it should be used in conjunction with the documentation provided for each component.

Software License Agreement

The software is provided under license agreements and may contain third-party software under separate third-party licensing. Refer to the license files provided with the software for specific details.

If You Need Help

Technical support for all Cornelis products is available 24 hours a day, 365 days a year.

For additional details:

New in This Release

The following features are new in this release:

  • Maintenance Updates

Firmware Components

This release contains the firmware components listed in the following table.

Firmware Components

Description

File Name

Version

Firmware Update Tool (includes updateAgent)

CN5000_FW_UPDATE_Agent-12.1.1.0.1.tgz

12.1.1.0



System Requirements

This section lists the supported hardware.

Supported Hardware

The following tables list the hardware supported in this release.

SuperNIC Products

Hardware

Description

CN5000 SuperNIC, CN5HFA2D5ALS

Dual Port, QSFP-DD, x16 PCIe Gen 5, Air-Cooled, Low Profile, Single

CN5000 SuperNIC, CN5HFA1Q5ALS

Single Port, QSFP, x16 PCIe Gen 5, Air-Cooled, Low Profile, Single

CN5000 SuperNIC, CN5HFA1Q5NLS

Single Port, QSFP, x16 PCIe Gen 5, Conduction-Cooled, Low Profile, Single



Installation Requirements

Refer to the CN5000 Maintenance and Troubleshooting Guide for instructions to update the switch firmware.

Best Practices
  • To obtain the most recent functional and security updates, Cornelis recommends that you download and install the latest versions of the CN5000 Omni-Path software and firmware. Software and Documentation are found in the Cornelis Customer Center.

  • To ensure optimal performance in your CN5000 fabric, it is important to review the Cornelis performance tuning recommendations in the CN5000 Performance Tuning Guide.

Issues

This section lists the resolved and open issues.

Resolved Issues

None.

Open Issues

The following table lists the open issues for this release.

Open Issues

ID

Description

Workaround

STL-75609

The updateAgent tool may become stuck when downgrading SuperNIC firmware.

Use updateAgent -f when downgrading firmware.

STL-73440

Running the updateAgent while the Fabric Manager is running may result in a segfault.

Disable the Fabric Manager prior to running the updateAgent.

STL-73195

When updating the SuperNIC firmware using updateAgent -v, the following error may occur:

While waiting for a response to PLDM type 05 and command code 14, a message with type 05 and command 15 was received 

Retry the updateAgent -v command.

STL-72988

STL-72556

When updating firmware in a CN5000 SuperNIC in a management node, updateAgent times out when the FM is running at the same time.

Run the updateAgent with the -m option, which will stop the Fabric Manager if it is running, and then automatically start it when firmware update is finished if it had been running.

Refer to the CN5000 Maintenance and Troubleshooting Guide, “Update the SuperNIC Firmware” for the full procedure.



Product Limitations

None.

Download PDF

Preface

This document provides an overview of the changes introduced in this release. References to more detailed information are provided where necessary. The information contained in this document is intended as supplemental information only; it should be used in conjunction with the documentation provided for each component.

Software License Agreement

The software is provided under license agreements and may contain third-party software under separate third-party licensing. Refer to the license files provided with the software for specific details.

If You Need Help

Technical support for all Cornelis products is available 24 hours a day, 365 days a year.

For additional details:

Release Compatibility

This release is backward compatible with the most recent minor release version. For example, Release 12.N is backward compatible with Release 12.N-1 and Release 12.N-1.x.

New in This Release

The following features are new in this release:

  • Maintenance Updates

Release Items

The following software package is available for this release:

CN5000_OPXSoftware-<DISTRO>-12.1.1.0.18.tgz

Note

OS RPMs may need to be installed prior to software installation. Dependencies will be flagged during installation.

The following table lists meta package files provided for this release.

Meta Packages

RPM Name

Description

RHEL and SLES

cn5000_pkgs_cuda_meta-12_1_1_0-18.x86_64.rpm

CN5000 Meta Package containing all of the required CUDA RPMs

cn5000_pkgs_non_gpu_meta-12_1_1_0-18.x86_64.rpm

CN5000 Meta Package containing all of the required RPMs

cn5000_pkgs_rocm_meta-12_1_1_0-18.x86_64.rpm

CN5000 Meta Package containing all of the required ROCm RPMs

Ubuntu

cn5000-pkgs-cuda-meta_12.1.1.0.18-amd64.deb

CN5000 Meta Package containing all of the required CUDA DEBs

cn5000-pkgs-non-gpu-meta_12.1.1.0.18-amd64.deb

CN5000 Meta Package containing all of the required DEBs

cn5000-pkgs-rocm-meta_12.1.1.0.18-amd64.deb

CN5000 Meta Package containing all of the required ROCm DEBs



Refer to Appendix E, Release Package Manifest for the list of RPM and DEB files provided in this release.

System Requirements

This section lists the compatible operating systems and supported hardware.

Operating Systems

This release of the CN5000 OPX Software supports the operating systems listed in the following table.

Supported Operating Systems for This Release 

Operating System

Base Kernel Version

RHEL 9.4

5.14.0-427.13.1el9_4.x86_64

RHEL 9.5

5.14.0-503.11.1.el9_5.x86_64

RHEL 9.6

5.14.0-570.12.1.el9_6.x86_64

RHEL 9.7

5.14.0-611.5.1.el9_7.x86_64

RHEL 10.0

6.12.0-55.9.1.el10_0.x86_64

Rocky Linux 9.5

5.14.0-503.14.1.el9_5.x86_64

Rocky Linux 9.6

5.14.0-570.17.1el9_6.x86_64

Rocky Linux 9.7

5.14.0-611.5.1.el9_7.x86_64

Rocky Linux 10.0

6.12.0-55.12.1.el10_0.x86_64

SLES 15 SP7

6.4.0-150700.53.22.1-default

Ubuntu 24.04 LTS

6.8.0-90-generic



Note

AMD ROCm versions 6.4.1 and onward are not supported on RHEL/Rocky 9.5. Refer to the ROCm Compatibility Matrix.

Supported Hardware

The following tables list the hardware supported in this release.

Switch Products

Hardware

Description

CN5000 Switch

CN5000 Switch, 48-Port, CN5SWE48G2AF

240/277 VAC in, Dual Power Supply, Air-Cooled, Fan-to-Port

CN5000 Switch, 48-Port, CN5SWE48G2AP

240/277 VAC in, Dual Power Supply, Air-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48G2WF

240/277 VAC in, Dual Power Supply, Liquid-Cooled, Fan-to-Port

CN5000 Switch, 48-Port, CN5SWE48G2WP

240/277 VAC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48D2AP

48 VDC in, Dual Power Supply, Air-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48D2WP

48 VDC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan

CN5000 Director Class Switch and Components

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAB

240/277 VAC in, Air-Cooled, Base Chassis

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAC

240/277 VAC in, Air-Cooled, FRU Chassis

CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48A

48-Port, Air-Cooled

CN5000 Director Class Switch, Spine Module, CN5SWDSP01A

Air-Cooled

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWB

240/277 VAC in, Liquid-Cooled, Base Chassis

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWC

240/277 VAC in, Liquid-Cooled, FRU Chassis

CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48W

48-Port, Liquid-Cooled

CN5000 Director Class Switch, Spine Module, CN5SWDSP01W

Liquid-Cooled



SuperNIC Products

Hardware

Description

CN5000 SuperNIC, CN5HFA2D5ALS

Dual Port, QSFP-DD, x16 PCIe Gen 5, Air-Cooled, Low Profile, Single

CN5000 SuperNIC, CN5HFA1Q5ALS

Single Port, QSFP, x16 PCIe Gen 5, Air-Cooled, Low Profile, Single

CN5000 SuperNIC, CN5HFA1Q5NLS

Single Port, QSFP, x16 PCIe Gen 5, Conduction-Cooled, Low Profile, Single



Processors

Hardware

Description

CPUs 

4th Gen AMD EPYC Processor 

Genoa Zen 4 CPU-based servers

5th Gen AMD EPYC Processor 

Turin Zen 5 CPU-based servers

4th Generation Intel Xeon Scalable Processor 

Sapphire Rapids CPU-based servers

5th Generation Intel Xeon Scalable Processor 

Emerald Rapids CPU-based servers

GPUs 

AMD Instinct MI Series GPU

AMD Instinct MI300X and MI200 series Graphic Processing Units

NVIDIA GPUs

NVIDIA Tesla V100 and later



Installation Requirements

Refer to the CN5000 Fabric Installation Guide for related software requirements and complete installation procedures.

Best Practices
  • To obtain the most recent functional and security updates, Cornelis recommends that you download and install the latest versions of the CN5000 Omni-Path software and firmware. Software and Documentation are found in the Cornelis Customer Center.

  • To ensure optimal performance in your CN5000 fabric, it is important to review the Cornelis performance tuning recommendations in the CN5000 Performance Tuning Guide.

Disable the Repository After OPX Software Installation

Required for RHEL 9.5.

  • After installing or updating the OPX Software, disable the repository on every node using one of the following methods:

    • Run the following command:     

      sudo dnf config-manager --set-disabled <repo>
    • In the repository file, change enable to 0.

Issues

This section lists the resolved and open issues.

Resolved Issues

The following table lists issues that are resolved in this release.

Issues Resolved in this Release

ID

Description

Resolved in Release

STL-76222

Memory overflow may occur when running MVAPICH on Ubuntu platforms.

12.1.1

STL-76135

When using SR-IOV, jobs running high processes per node (PPN) may fail on virtual machines with limited resources.

12.1.1

STL-75555

Errors can occur when installing Ubuntu meta-packages with apt or apt-get if the required dependencies are not the latest versions available on Ubuntu. Added to CN5000 Fabric Installation Guide, “Install the OPX Software”

12.1.1

STL-75331

Using RDMA Core persistent names with settings other than KERNEL will result in RCCL segmentation faults.

12.1.1

STL-70422

RCCL hangs on AMD GPUs with opx and aws-ofi-rccl plugin.

12.1.1

STL-76376

Kernel crash may occur when hfi1 module is loaded with use_bulksvc=Y.

12.1.0.1

STL-76375

MPI or middleware using the OPX Libfabric Provider may experience unreliable results.

12.1.0.1

STL-76373

Benign hfi1 messages relating to MCTXT interrupt in kernel logs can be ignored.

12.1.0.1

STL-75066

If IPv6 is enabled on any IPoIB interfaces, the FM sweeps constantly due to changes in multicast group membership.

12.1.0

STL-74951

STL-74672

On rare occasions, application hangs with an SDMA engine error in DMSG have been observed.

12.1.0

STL-74696

When running an NVIDIA GPU Cloud (NGC) container such as the "NVIDIA HPC-Benchmarks" package, a segmentation fault may occur.

12.1.0

STL-74672

On rare occasions, application hangs with an SDMA engine error in DMSG have been observed.

12.1.0

STL-74234

The mvapich2 packages provided with OPX Software should be ignored and not used.

12.1.0

STL-74218

IPoIB interfaces on CN5000 currently do not support failover with the Channel Bonding driver in the Linux kernel.

12.1.0

STL-73861

Hangs occur when using NVMe over Fabric.

12.1.0

STL-73759

When the FM restarts, different LIDs may get assigned to the nodes.

12.1.0

STL-73267

When running the opasmaquery -o portinfo - g command, the output does not display a value for VLSchedulingConfig.

12.1.0

STL-73245

CN5000 Switch-Switch links do not appear in either opareport -o extlinks or opareport -o extislinks command output.

12.1.0

STL-72864

High CPU utilization seen for hfi1 related interrupts, potentially impacting performance.

12.1.0

STL-72815

opapaquery -o vfConfig -V 'Default' may display duplicated port entries.

12.1.0

STL-72640

In some cases the dmesg log may contain a message stating:

hfi1_tid_rdma_flush_wait: no rcd for QP

12.1.0

STL-72575

TID updates under heavy load may result in an -ENOMEM error.

12.1.0

STL-72572

In opasmaquery -o swinfo, there is no indication whether the CN5000 fine-grained adaptive routing (FGAR) is supported.

12.1.0

STL-72547

Class Port Info queries are not reporting properly.

12.1.0



Open Issues

The following tables list the open issues for this release.

Open Issues

ID

Description

Workaround

STL-76942

Lustre errors occur with Bulk Transfer Service (BTS) enabled (hfi1 driver parameter use_bulksvc=Y).

When mounting Lustre, BTS should not be enabled (use_bulksvc=N, which is default).

STL-76907

The following Lustre Error may occur:

Write request failed with -14

NOTE: This is a general defect that affects all Lustre 2.17.0 stacks (refer to Lustre-Release Issue #16

Avoid this issue by disabling hybrid IO functionality using the following command on the MGS server:

lctl set_param -P llite.*.hybrid_io=0

STL-76435

opapmaquery fails with the following error when querying performance counters for more than approximately 14 ports simultaneously on a single switch.

Invalid Attribute or Attribute Modifier

NOTE: The PMA response has a maximum payload size that limits the number of ports that can be returned in a single query.

Split the port select mask (-n option) into multiple smaller queries, each covering a subset of ports.

For example, on a 48-port switch, query ports in groups of 20 or fewer:

opapmaquery -o getdatacounters -l <LID> -n 0x0000000FFFFF # ports 0-19

opapmaquery -o getdatacounters -l <LID> -n 0x00FFFFF00000 # ports 20-39

opapmaquery -o getdatacounters -l <LID> -n 0xFF0000000000 # ports 40-47

STL-76348

Running opapaquery -o focusport reports same neighbor LID if the switch is connected to a dual-port SuperNIC.

None.

STL-76323

SuperNICs may intermittently fail to enumerate on the PCIe bus or initialize after a cold boot or power cycle. In affected systems, one or more SuperNICs may be absent from the OS, preventing the node from participating in the fabric until the device is successfully detected and initialized.

Power cycle the server.

STL-76313

Kernel messages such as the following may be seen:

CPORT request wait interrupted
Dropping incoming CPORT message

Set the hfi1 module parameter cport_mad_to=5.

STL-76263

In some circumstances, rebooting a host may cause a panic.

Power cycle the system.

STL-76144

Setting the link speed policy to 100G in the opafm.xml file results in the following Fabric Manager error:

Invalid Value for Link Speed Policy: 100G

Set the link speed using the Switch CLI command port modify speed.

STL-76137

Open MPI traffic fails on SR-IOV Virtual Function devices.

Use the oversubscribe option.

STL-76131

When using SR-IOV, the dmesg log in the VMs may occasionally show the following warning message:

memcpy: detected field-spanning write

Do not run Omni-Path management tools, such as opafabricinfo, on virtual machines. These tools should only be run on the host.

STL-76108

SR-IOV Virtual Function devices on CN5000 cannot query the Subnet Administration.

Do not run tools such as opareport or opasmquery on Virtual Function interfaces. Run them only on Physical Function interfaces.

STL-75568

Performance test failures may occur when running ib_send_bw and ib_read_bw with the -D (duration) option.

Do not use the -D option.

STL-75535

GADGET4 MPI application hangs with OPX Provider.

Contact support@cornelis.com.

STL-75526

After installing the OPX Software package on Ubuntu, the opafm service is enabled by default.

Manually disable the opafm service by default.

STL-75484

Running opaportconfig with the disable option immediately followed by running opaportconfig with the enable option will result in the link staying down.

To drop and reinitialize a link, use the bounce option to opaportconfig.

Alternately, if opaportconfig is run from a script, insert a one second delay (sleep 1) between the disable and enable commands.

STL-75395

When AdaptiveRouting is enabled in the opafm.xml file, but FineGrained is not, the Fabric Manager will crash.

Disable AdaptiveRouting in the opafm.xml file and restart the Fabric Manager.

STL-75394

On some systems running Ubuntu 24.04, the hfi1 driver may fail to start when it is unloaded and reloaded. The system log will contain a message saying CPORT start failed.

If this message is seen, unload and reload the hfi1 driver again.

STL-75362

When using the TCP provider of libfabric, some MPI application may perform poorly or hang when launched with 1 process per core. This has been observed in benchmarks such as OSU Congestion, OSU Collectives, and IMB P2P.

For best results, users should use the OPX provider whenever available. OPX can be explicitly selected by setting the environment variable, FI_PROVIDER=opx.

STL-75322

Upon reverting from 12.0.3 to a previous RHEL/Rocky release certain packages may not be removed.

Use the following command to remove the remaining packages:

dnf remove ibacm infiniband-diags 
libfabric libhfi1verbs libibumad 
libibverbs libpsm2 librdmacm 
librdmacm-utils mpi-selector 
opa-basic-tools opa-fastfabric 
opa-fm opa-libopamgt rdma-core 
rdma-core-devel srp_daemon

STL-75031

STL-76644

MPI RMA benchmarks may produce an SDMA error (bad address) when using the OPX libfabric provider and environment variable FI_OPX_MIXED_NETWORK=0.

FI_OPX_MIXED_NETWORK is deprecated and should no longer be set. Contact support@cornelis.com.

STL-74968

Updating the Fabric Manager using DNF may not succeed even though an update is available.

Perform the following:

  1. Uninstall the current opa-fm package.

  2. Install the opa-fm package using:

    dnf install opa-fm-<full version name>

STL-74933

Entries of the form hfi1_0: lost_mctxt_intr forcing int for 2 and MCTXT interrupt, but no status bits set may appear in logs.

These messages can be ignored.

STL-74679

While running IPoIB in Connected mode, application hangs have been observed.

Configure IPoIB to Datagram mode and rerun the application.

STL-74625

When using both ports of a dual-port SuperNIC, the ibstat rate field may show an incorrect value.

Use opainfo, which is the preferred method for querying port information.

STL-74593

The Quantum Espresso application with Intel MPI may abort with SIGABRT when executed with a higher number of MPI ranks than available user HFI contexts and multiple endpoints per HFI context (FI_OPX_ENDPOINTS_PER_HFI_CONTEXT=2)

Set FI_OPX_ENDPOINTS_PER_HFI_CONTEXT=1 and reduce the number of MPI ranks to be less than or equal to the number of available HFI user contexts.

STL-74504

Occasional drops in bandwidth observed during microbenchmark testing.

Refer to the Performance Tuning Guide for platform-specific tuning.

STL-74477

Building opxs-kernel-updates from the src.rpm file fails with nvidia/nv-p2p.h not detected.

Use an environment variable to allow the header file to be detected and used in the build:

NVIDIA_DIR=$(ls -d /usr/src/nvidia-* | head -1) 
ln -s ${NVIDIA_DIR}/nvidia /usr/src/kernels/5.14.0-503.14.1.el9_5.x86_64/include/nvidia

Note that the exact directory required for the symbolic link will depend on your kernel version.

STL-74230

IPoIB interfaces on CN5000 currently do not support failover with the Channel Bonding driver in the Linux kernel.

No workaround.

STL-74025

When using IPoIB on CN5000, SuperNICs do not change MTU or join MC groups automatically.

Use the ip tool from the command line to manually take the interface down and back up.

STL-73928

HFI links bounce and the SM reports mapping warnings following the second FM restart.

No Workaround. Links that bounce recover and the fabric stabilizes.

STL-73738

Reloading the ipoib kernel module without also reloading the hfi1 module may cause FM errors.

To avoid this, always reload the hfi1 module along with the ipoib module.

STL-73716

The opatop and opapaquery commands may report congestion incorrectly when the fabric is idle.

Ignore the congestion flag.

STL-73714

Performing an opapmaquery to a "B" port on a switch where subdivision is not enabled returns non-zero counter values.

Counter values in this scenario should be ignored.

STL-73713

In a fabric with no data traffic, the Xmit Time Congestion port counter will increment.

No workaround.

STL-73709

The opasaquery -o trace -P (GUIDs) and opasaquery -o trace -G (GIDs) commands fail when targeting CN5000 SuperNIC cards.

No workaround.

STL-73669

Executing opasmaquery -o scvlr for nodes that do not support SC-VLr mappings will result in a message indicating a failure.

The message may be ignored.

STL-73531

Configuring more than two data VLs is not currently supported. Doing so may lead to incorrect mappings of SC to VL.

Limit the number of configured data VLs to two.

STL-73330

Some LS-DYNA R14.1.0. benchmarks hang with Open MPI when using the OPX Provider for libfabric.

Set the environment variable FI_OPX_RELIABILITY_SERVICE_USEC_MAX=5000.

STL-73215

When running opasmaquery -o sminfo on CN5000 SuperNICs, SMA fields show all 0s and SM State Inactive.

Use opasaquery -o sminfo or opareport to show correct SA SMInfo data.

STL-73160

The comments in the Adaptive Routing section of the opafm.xml file do not explain which settings are required for MGAR or for FGAR.

Currently the only field related to FGAR is FineGrained. In order to enable FGAR, set the following:

<AdaptiveRouting>1</AdaptiveRouting> 

<FineGrained>1</FineGrained> 

All other fields are related to legacy MGAR and will be ignored if FineGrained is enabled.

STL-73140

The following CN5000 commands do not work as expected:

  • opaextractbadlinks 

  • opafabricanalysis 

  • opahfirev 

  • opapacketcapture 

  • opaverifyhosts 

Note the following:

  • opapacketcapture must be invoked as opapacketcapture -d /dev/hfi1_0_diagpkt2 for SuperNICs due to its default port 2.

  • opaverifyhost can take up to one minute to execute.

  • All other commands currently have no workarounds.

STL-72673

OS-release file captured by opacapture is empty. 

Use cat /etc/os-release command.

STL-72649

An Open MPI error may occur when using --mca btl self,vader and RMA-style functionality (for example, the OSU Put and Get test or IMB-RMA).

Contact support@cornelis.com.

STL-72583

In some cases the dmesg log may contain a message stating:

invalid logical state transition PORT_DOWN > PORT_ACTIVE.

This is cosmetic and will not affect functionality.

STL-72573

Hangs and errors have been seen in the OSU alltoall collective test when using the OPX Provider to libfabric with ROCm.

No workaround.

STL-72541

Running the opainfo command when ports are inactive results in the following errors: MAD failed and Failed to get PMA Port Status.

These errors can be ignored.

STL-72536

STL-72537

CableInfo errors encountered when using the opasmaquery -o cableinfo command.

Cable information reporting not currently supported.

STL-72526

The Fabric Manager system log port numbering is different from Switch CLI command port numbering.

The port number used by the FM is equivalent to twice the switch CLI port name minus one. Contact Cornelis Customer Support for details.

STL-72523

Errors occur on RHEL 9.5 after installation of meta package.

Refer to Disable the Repository After OPX Software Installation.

STL-72431

The command opasaquery -o node -n [NodeGUID] results in output of No Records Returned. 

Use opsmaquery -o nodeinfo -l 4, where l corresponds to the LID of the node.

STL-72420

On some versions of RHEL 9.x, there is a known failure (rdmavt driver deadlock.) recorded in https://issues.redhat.com/browse/RHEL-83851.

NOTE: Cornelis has not replicated this problem but it is possible that customers may be affected.

No workaround.

STL-72205

FI_OPX_HFI_SELECT=[] does not correctly map to the available adapter in the case in which other adapters in the system have been disabled.

Unload and reload the driver.

STL-72160

After uninstalling the meta packages with a package manager, several Cornelis Networks packages remain.

Refer to the CN5000 Maintenance and Troubleshooting Guide, “Remove OPX Software from a Host” for removal of the remaining packages.

STL-71364

STL-72423

Some legacy Omni-Path host utilities have been deprecated for CN5000 but are still supported for OPA100.   

For a list of commands supported for CN5000, refer to the Man Pages or CN5000 Commands Guide.

STL-67178

After boot, the OPX Software hfi1-NVIDIA support is not available.

Review boot configuration to ensure that nvidia-driver will be available when hfi1 is loaded.



Product Limitations

This release has the following limitations:

  • Bulk Transfer Service is not available on port 1 of dual port SuperNIC cards.

  • When running MVAPICH3 with the OPX provider of libfabric, a *** buffer overflow detected *** error may cause the job to terminate. This issue has been observed when running with a high number of processes, particularly when using 1 process per core (that is, the maximum number of processes the system can support). A workaround is to set environment variable, MV2_ENABLE_AFFINITY=0 to disable CPU affinity.

  • Queries to single port adapters will reflect that there are two ports with the first port always showing as offline.

  • Running of MPI jobs across both CN5000 and OPA100 components in hybrid fabrics (fabrics where CN5000 and OPA100 are connected) is not presently supported.

  • In the opafm.xml file, the default HFI port for fm0 must be set to "2" for proper operation:

    <Name>fm0</Name>    
    <Hfi>1</Hfi>     
    <Port>2</Port> 
  • Non-default MinShareVLMem and DedicatedVLMem values are not supported. Only use default values.

  • FM Failover is presently not supported. Use a single Fabric Manager.

  • NVMe over Fabric is currently not supported.

  • Some distros versions may ship with ib_qib driver enabled. This driver is incompatible with the CN5000 OPX Software and may result in errors such as disagrees about version of symbol in logs. Set blacklist ib_qib.

  • During link bring up on a mixed OPA100/CN5000 fabric the FM log may show "Mismatch/Unable to set SCVL_t Map" warnings and link bounces may be observed as the fabric comes up. These messages and link bounces are expected on mixed fabrics and do not indicate a fault.

  • Enabling vFabrics with QoS results in Neighbor Mismatch/Unable to set SCVL_nt Map and Failed to init SL Maps in the log, and port bounces. There is no workaround. Port bounces are part of the standard recovery mechanism. These messages should only occur once and only when there is a change in the SCVL maps.

  • opainfo displays a single port adapter as a dual port adapter. No workaround. This is informational.

  • Ubuntu server fails to boot with more than one CN5000 SuperNIC installed. Ubuntu platforms cannot host multiple SuperNICs.

  • Bulk Transfer Service (BTS, bulksvc) is not supported on GPU platforms.

  • MVAPICH-Plus 4.1 for GPU is not supported.

Download PDF

Preface

This document provides an overview of the changes introduced in this release. References to more detailed information are provided where necessary. The information contained in this document is intended as supplemental information only; it should be used in conjunction with the documentation provided for each component.

Software License Agreement

The software is provided under license agreements and may contain third-party software under separate third-party licensing. Refer to the license files provided with the software for specific details.

If You Need Help

Technical support for all Cornelis products is available 24 hours a day, 365 days a year.

For additional details:

New in This Release

The following features are new in this release:

  • Single Root I/O Virtualization (SR-IOV)

  • Maintenance Updates

Firmware Components

This release contains the firmware components listed in the following table.

Firmware Components

Description

File Name

Version

SuperNIC Firmware

CN5000.SuperNICFirmware-12.1.1.0.6-V1.pkg

12.1.1.0



System Requirements

This section lists the supported hardware.

Supported Hardware

The following tables list the hardware supported in this release.

SuperNIC Products

Hardware

Description

CN5000 SuperNIC, CN5HFA2D5ALS

Dual Port, QSFP-DD, x16 PCIe Gen 5, Air-Cooled, Low Profile, Single

CN5000 SuperNIC, CN5HFA1Q5ALS

Single Port, QSFP, x16 PCIe Gen 5, Air-Cooled, Low Profile, Single

CN5000 SuperNIC, CN5HFA1Q5NLS

Single Port, QSFP, x16 PCIe Gen 5, Conduction-Cooled, Low Profile, Single



Installation Requirements

Refer to the CN5000 Maintenance and Troubleshooting Guide for instructions to update the switch firmware.

Best Practices
  • To obtain the most recent functional and security updates, Cornelis recommends that you download and install the latest versions of the CN5000 Omni-Path software and firmware. Software and Documentation are found in the Cornelis Customer Center.

  • To ensure optimal performance in your CN5000 fabric, it is important to review the Cornelis performance tuning recommendations in the CN5000 Performance Tuning Guide.

Issues

This section lists the resolved and open issues.

Resolved Issues

The following table lists issues that are resolved in this release.

Issues Resolved in this Release

ID

Description

Resolved in Release

STL-75192

In some rare cases, the host system may hang on a warm reboot.

12.1.1

STL-74377

In rare cases, nodes may drop from fabric with unreachable CPORT when attempting to delete or reset an IPoIB interface.

12.1.0

STL-73920

System Image GUID is the same on all SuperNICs.

12.1.0

STL-73153

The SuperNIC firmware version is currently displayed differently in different places, such as the system log versus the updateAgent.

12.1.0

STL-72796

iperf2 may occasionally hang with an SDMA status error.

12.1.0

STL-72644

While using a QSFP cable, you may see warnings in host logs regarding RxDmaDataFifoRdCorErr (QSFP-DD lanes not used).

12.1.0

STL-72640

In some cases the dmesg log may contain a message stating:

hfi1_tid_rdma_flush_wait: no rcd for QP

12.1.0

STL-72360

After IMB-RMA Uniband operation, occasional tasks may freeze.

12.1.0



Open Issues

The following table lists the open issues for this release.

Open Issues

ID

Description

Workaround

STL-76776

Network connectivity may fail after hot swapping cables of different types on the SuperNIC.

Reboot the host to detect the new cables.

STL-76323

SuperNICs may intermittently fail to enumerate on the PCIe bus or initialize after a cold boot or power cycle. In affected systems, one or more SuperNICs may be absent from the OS, preventing the node from participating in the fabric until the device is successfully detected and initialized.

Power cycle the server.

STL-75884

PXE boot fails after changing the default Fabric Manager SubnetPrefix.

Restore the Fabric Manager SubnetPrefix to the default value 0xfe80000000000000.

STL-75609

The updateAgent tool may become stuck when downgrading SuperNIC firmware.

Use updateAgent -f when downgrading firmware.

STL-75486

In rare cases, the driver may encounter an error as it loads. You will see errors in the dmesg log saying sysfs: cannot create duplicate filename.

Reboot the host and then load the hfi1 driver.

STL-74502

When updating SuperNIC firmware with multiple SuperNIC adapters in a server, some cards may fail to properly update.

Disable the port on the failed SuperNIC cards using opaportconfig -p n disable (where “n” is the port number) and perform the update again.

STL-73738

Reloading the ipoib kernel module without also reloading the hfi1 module may cause FM errors.

To avoid this, always reload the hfi1 module along with the ipoib module.

STL-73709

The opasaquery -o trace -P (GUIDs) and opasaquery -o trace -G (GIDs) commands fail when targeting CN5000 SuperNIC cards.

No workaround.

STL-73440

Running the updateAgent while the Fabric Manager is running may result in a segfault.

Disable the Fabric Manager prior to running the updateAgent.

STL-73195

When updating the SuperNIC firmware using updateAgent -v, the following error may occur:

While waiting for a response to PLDM type 05 and command code 14, a message with type 05 and command 15 was received

Retry the updateAgent -v command.

STL-73153

The SuperNIC firmware version is currently displayed differently in different places, such as the system log versus the updateAgent.

Use updateAgent -V when checking the SuperNIC firmware version.

STL-73088

On some dual-port devices, inbound IPoIB traffic may fail after a system reboot, or after restarting the FM and IPoIB interfaces on the FM node.

Ping out from the unreachable interface, and IP traffic will resume.

STL-72988

STL-72556

When updating firmware in a CN5000 SuperNIC in a management node, updateAgent times out when the FM is running at the same time.

Run the updateAgent with the -m option, which will stop the Fabric Manager if it is running, and then automatically start it when firmware update is finished if it had been running.

Refer to the CN5000 Maintenance and Troubleshooting Guide, “Update the SuperNIC Firmware” for the full procedure.

STL-72817

When reading hfi1 port counters from sysfs, you will receive an Invalid Argument return code.

This message can be ignored.

STL-72598

In some cases, when unloading hfi1 or ib_ipoib, the dmesg log may display an error stating:

hfi1_tid_rdma_flush_wait: no rcd for QP

This message can be safely ignored.

STL-72583

In some cases the dmesg log may contain a message stating:

invalid logical state transition PORT_DOWN > PORT_ACTIVE.

This is cosmetic and will not affect functionality.

STL-71647

On rare occasions, the link may come up at a width less than 4X.

Bounce the link.



Product Limitations

This release has the following product limitations:

  • lspci does not enumerate the CN5000 SuperNIC with ASPM enabled, causing the BIOS screen on Intel D50DNP platforms to lock up. Disable ASPM in the BIOS.

  • Bulk Transfer Service is not available on port 1 of dual port SuperNIC cards.

  • SuperNICs received from Cornelis with firmware version prior to 12.0.2.0.6 do not include UEFI (Option ROM). Contact Cornelis Customer Support for firmware and update procedures.

  • Update agent fails to update the SuperNIC Firmware when the OPX Software version is 12.0.2 or newer and SuperNIC Firmware is version is 12.0.1.

    To work around this limitation, reduce OPX Software version to 12.0.1, update the SuperNIC Firmware to version 12.0.2, then reinstall the 12.0.2 or newer OPX Software.

  • CN5000 SuperNIC enumerates at x4 PCIe width on some platforms if the width is not forced to x16 in the BIOS. Configure the BIOS to enforce PCIe x16 width.

Download PDF

Preface

This document provides an overview of the changes introduced in this release. References to more detailed information are provided where necessary. The information contained in this document is intended as supplemental information only; it should be used in conjunction with the documentation provided for each component.

Software License Agreement

The software is provided under license agreements and may contain third-party software under separate third-party licensing. Refer to the license files provided with the software for specific details.

If You Need Help

Technical support for all Cornelis products is available 24 hours a day, 365 days a year.

For additional details:

New in This Release

The following features are new in this release:

  • Maintenance Updates

Firmware Components

This release contains the firmware components listed in the following table.

Firmware Components

Description

File Name

Version

Switch Firmware

CN5000.SwitchFirmware-12.1.1.0.6-V1.pkg

12.1.1.0



System Requirements

This section lists the supported hardware.

Supported Hardware

The following tables list the hardware supported in this release.

Switch Products

Hardware

Description

CN5000 Switch

CN5000 Switch, 48-Port, CN5SWE48G2AF

240/277 VAC in, Dual Power Supply, Air-Cooled, Fan-to-Port

CN5000 Switch, 48-Port, CN5SWE48G2AP

240/277 VAC in, Dual Power Supply, Air-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48G2WF

240/277 VAC in, Dual Power Supply, Liquid-Cooled, Fan-to-Port

CN5000 Switch, 48-Port, CN5SWE48G2WP

240/277 VAC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48D2AP

48 VDC in, Dual Power Supply, Air-Cooled, Port-to-Fan

CN5000 Switch, 48-Port, CN5SWE48D2WP

48 VDC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan

CN5000 Director Class Switch and Components

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAB

240/277 VAC in, Air-Cooled, Base Chassis

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAC

240/277 VAC in, Air-Cooled, FRU Chassis

CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48A

48-Port, Air-Cooled

CN5000 Director Class Switch, Spine Module, CN5SWDSP01A

Air-Cooled

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWB

240/277 VAC in, Liquid-Cooled, Base Chassis

CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWC

240/277 VAC in, Liquid-Cooled, FRU Chassis

CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48W

48-Port, Liquid-Cooled

CN5000 Director Class Switch, Spine Module, CN5SWDSP01W

Liquid-Cooled



Installation Requirements

Refer to the CN5000 Maintenance and Troubleshooting Guide for instructions to update the switch firmware.

Best Practices
  • To obtain the most recent functional and security updates, Cornelis recommends that you download and install the latest versions of the CN5000 Omni-Path software and firmware. Software and Documentation are found in the Cornelis Customer Center.

  • To ensure optimal performance in your CN5000 fabric, it is important to review the Cornelis performance tuning recommendations in the CN5000 Performance Tuning Guide.

Issues

This section lists the resolved and open issues.

Resolved Issues

The following table lists the resolved issues for this release.

Issues Resolved in this Release

ID

Description

Resolved in Release

STL-75508

When using the node description to query, the name has a trailing space.

12.1.0

STL-73399

After rebooting the switch ASIC, port commands may show invalid information until the switch ASIC has completed initialization.

12.1.0

STL-73029

BEL DC power supplies VOUT_MODE command returns incorrect results.

12.1.0



Open Issues

The following table lists the open issues for this release.

Open Issues

ID

Description

Workaround

STL-74370

ASIC firmware update may fail with the following message:

Error during firmware update

Not that this message is seen when checking the status using the firmware update -s command.

Retry the ASIC firmware update.

STL-73361

On rare occasions, links connecting a CN5000 switch to an OPA100 adapter may unexpectedly bounce.

No action required, the link will self recover.

STL-72526

The Fabric Manager system log port numbering is different from Switch CLI command port numbering.

For details, contact support@cornelis.com for technical advisory TA0061.

STL-71647

On rare occasions, the link may come up at a width less than 4X.

Bounce the link.



Product Limitations

None.