Switch Firmware
Preface
This document provides an overview of the changes introduced in this release. References to more detailed information are provided where necessary. The information contained in this document is intended as supplemental information only; it should be used in conjunction with the documentation provided for each component.
Software License Agreement
The software is provided under license agreements and may contain third-party software under separate third-party licensing. Refer to the license files provided with the software for specific details.
If You Need Help
Technical support for all Cornelis products is available 24 hours a day, 365 days a year.
For additional details:
Visit the Cornelis Support page at http://www.cornelisnetworks.com/support
Contact email: support@cornelisnetworks.com
New in This Release
The following features are new in this release:
Maintenance Updates
Firmware Components
This release contains the firmware components listed in the following table.
Description | File Name | Version |
|---|---|---|
Switch Firmware | CN5000.SwitchFirmware-12.4.0.0.6-V1.pkg | 12.4.0 |
System Requirements
This section lists the supported hardware.
Supported Hardware
The following tables list the hardware supported in this release.
Hardware | Description |
|---|---|
CN5000 Switch | |
CN5000 Switch, 48-Port, CN5SWE48G2AF | 240/277 VAC in, Dual Power Supply, Air-Cooled, Fan-to-Port |
CN5000 Switch, 48-Port, CN5SWE48G2AP | 240/277 VAC in, Dual Power Supply, Air-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48G2WF | 240/277 VAC in, Dual Power Supply, Liquid-Cooled, Fan-to-Port |
CN5000 Switch, 48-Port, CN5SWE48G2WP | 240/277 VAC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48D2AP | 48 VDC in, Dual Power Supply, Air-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48D2WP | 48 VDC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan |
CN5000 Director Class Switch and Components | |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAB | 240/277 VAC in, Air-Cooled, Base Chassis |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAC | 240/277 VAC in, Air-Cooled, FRU Chassis |
CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48A | 48-Port, Air-Cooled |
CN5000 Director Class Switch, Spine Module, CN5SWDSP01A | Air-Cooled |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWB | 240/277 VAC in, Liquid-Cooled, Base Chassis |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWC | 240/277 VAC in, Liquid-Cooled, FRU Chassis |
CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48W | 48-Port, Liquid-Cooled |
CN5000 Director Class Switch, Spine Module, CN5SWDSP01W | Liquid-Cooled |
Installation Requirements
Refer to the CN5000 Maintenance and Troubleshooting Guide for instructions to update the switch firmware.
Best Practices
To obtain the most recent functional and security updates, Cornelis recommends that you download and install the latest versions of the CN5000 Omni-Path software and firmware. Software and Documentation are found in the Cornelis Customer Center.
To ensure optimal performance in your CN5000 fabric, it is important to review the Cornelis performance tuning recommendations in the CN5000 Performance Tuning Guide.
Issues
This section lists the resolved and open issues.
Resolved Issues
The following table lists the resolved issues for this release.
ID | Description | Resolved in Release |
|---|---|---|
STL-71647 | On rare occasions, the link may come up at a width less than 4X. | 12.4.0 |
Open Issues
The following table lists the open issues for this release.
ID | Description | Workaround |
|---|---|---|
STL-74480 | When a switch port operating in subdivided (2X) mode is disabled and re-enabled, it does not return to full-width 4X mode. | After replacing a bifurcated (Y-cable) connection with a straight QSFP cable, a switch power cycle is required to restore the port to 4X mode. |
STL-74370 | ASIC firmware update may fail with the following message: Error during firmware update Not that this message is seen when checking the status using the | Retry the ASIC firmware update. |
STL-73361 | On rare occasions, links connecting a CN5000 switch to an OPA100 adapter may unexpectedly bounce. | No action required, the link will self recover. |
STL-72526 | The Fabric Manager system log port numbering is different from Switch CLI command port numbering. | For details, contact support@cornelis.com for technical advisory TA0061. |
Product Limitations
This release has the following product limitations:
Updating the switch components (BMC/ASIC) in-band with the firmware update tool fails if the switch is running firmware older 12.2.x. You must update the firmware to 12.2 or greater before using in-band firmware updates.
Preface
This document provides an overview of the changes introduced in this release. References to more detailed information are provided where necessary. The information contained in this document is intended as supplemental information only; it should be used in conjunction with the documentation provided for each component.
Software License Agreement
The software is provided under license agreements and may contain third-party software under separate third-party licensing. Refer to the license files provided with the software for specific details.
If You Need Help
Technical support for all Cornelis products is available 24 hours a day, 365 days a year.
For additional details:
Visit the Cornelis Support page at http://www.cornelisnetworks.com/support
Contact email: support@cornelisnetworks.com
New in This Release
The following features are new in this release:
Maintenance Updates
Firmware Components
This release contains the firmware components listed in the following table.
Description | File Name | Version |
|---|---|---|
Switch Firmware | CN5000.SwitchFirmware-12.3.0.0.19-V1.pkg | 12.3.0 |
System Requirements
This section lists the supported hardware.
Supported Hardware
The following tables list the hardware supported in this release.
Hardware | Description |
|---|---|
CN5000 Switch | |
CN5000 Switch, 48-Port, CN5SWE48G2AF | 240/277 VAC in, Dual Power Supply, Air-Cooled, Fan-to-Port |
CN5000 Switch, 48-Port, CN5SWE48G2AP | 240/277 VAC in, Dual Power Supply, Air-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48G2WF | 240/277 VAC in, Dual Power Supply, Liquid-Cooled, Fan-to-Port |
CN5000 Switch, 48-Port, CN5SWE48G2WP | 240/277 VAC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48D2AP | 48 VDC in, Dual Power Supply, Air-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48D2WP | 48 VDC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan |
CN5000 Director Class Switch and Components | |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAB | 240/277 VAC in, Air-Cooled, Base Chassis |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAC | 240/277 VAC in, Air-Cooled, FRU Chassis |
CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48A | 48-Port, Air-Cooled |
CN5000 Director Class Switch, Spine Module, CN5SWDSP01A | Air-Cooled |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWB | 240/277 VAC in, Liquid-Cooled, Base Chassis |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWC | 240/277 VAC in, Liquid-Cooled, FRU Chassis |
CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48W | 48-Port, Liquid-Cooled |
CN5000 Director Class Switch, Spine Module, CN5SWDSP01W | Liquid-Cooled |
Installation Requirements
Refer to the CN5000 Maintenance and Troubleshooting Guide for instructions to update the switch firmware.
Best Practices
To obtain the most recent functional and security updates, Cornelis recommends that you download and install the latest versions of the CN5000 Omni-Path software and firmware. Software and Documentation are found in the Cornelis Customer Center.
To ensure optimal performance in your CN5000 fabric, it is important to review the Cornelis performance tuning recommendations in the CN5000 Performance Tuning Guide.
Issues
This section lists the resolved and open issues.
Resolved Issues
None.
Open Issues
The following table lists the open issues for this release.
ID | Description | Workaround |
|---|---|---|
STL-74480 | When a switch port operating in subdivided (2X) mode is disabled and re-enabled, it does not return to full-width 4X mode. | After replacing a bifurcated (Y-cable) connection with a straight QSFP cable, a switch power cycle is required to restore the port to 4X mode. |
STL-74370 | ASIC firmware update may fail with the following message: Error during firmware update Not that this message is seen when checking the status using the | Retry the ASIC firmware update. |
STL-73361 | On rare occasions, links connecting a CN5000 switch to an OPA100 adapter may unexpectedly bounce. | No action required, the link will self recover. |
STL-72526 | The Fabric Manager system log port numbering is different from Switch CLI command port numbering. | For details, contact support@cornelis.com for technical advisory TA0061. |
STL-71647 | On rare occasions, the link may come up at a width less than 4X. | Bounce the link. |
Product Limitations
This release has the following product limitations:
Updating the switch components (BMC/ASIC) in-band with the firmware update tool fails if the switch is running firmware older 12.2.x. You must update the firmware to 12.2 or greater before using in-band firmware updates.
Preface
This document provides an overview of the changes introduced in this release. References to more detailed information are provided where necessary. The information contained in this document is intended as supplemental information only; it should be used in conjunction with the documentation provided for each component.
Software License Agreement
The software is provided under license agreements and may contain third-party software under separate third-party licensing. Refer to the license files provided with the software for specific details.
If You Need Help
Technical support for all Cornelis products is available 24 hours a day, 365 days a year.
For additional details:
Visit the Cornelis Support page at http://www.cornelisnetworks.com/support
Contact email: support@cornelisnetworks.com
New in This Release
The following features are new in this release:
Maintenance Updates
Firmware Components
This release contains the firmware components listed in the following table.
Description | File Name | Version |
|---|---|---|
Switch Firmware | CN5000.SwitchFirmware-12.2.0.0.13-V1.pkg | 12.2.0 |
System Requirements
This section lists the supported hardware.
Supported Hardware
The following tables list the hardware supported in this release.
Hardware | Description |
|---|---|
CN5000 Switch | |
CN5000 Switch, 48-Port, CN5SWE48G2AF | 240/277 VAC in, Dual Power Supply, Air-Cooled, Fan-to-Port |
CN5000 Switch, 48-Port, CN5SWE48G2AP | 240/277 VAC in, Dual Power Supply, Air-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48G2WF | 240/277 VAC in, Dual Power Supply, Liquid-Cooled, Fan-to-Port |
CN5000 Switch, 48-Port, CN5SWE48G2WP | 240/277 VAC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48D2AP | 48 VDC in, Dual Power Supply, Air-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48D2WP | 48 VDC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan |
CN5000 Director Class Switch and Components | |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAB | 240/277 VAC in, Air-Cooled, Base Chassis |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAC | 240/277 VAC in, Air-Cooled, FRU Chassis |
CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48A | 48-Port, Air-Cooled |
CN5000 Director Class Switch, Spine Module, CN5SWDSP01A | Air-Cooled |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWB | 240/277 VAC in, Liquid-Cooled, Base Chassis |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWC | 240/277 VAC in, Liquid-Cooled, FRU Chassis |
CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48W | 48-Port, Liquid-Cooled |
CN5000 Director Class Switch, Spine Module, CN5SWDSP01W | Liquid-Cooled |
Installation Requirements
Refer to the CN5000 Maintenance and Troubleshooting Guide for instructions to update the switch firmware.
Best Practices
To obtain the most recent functional and security updates, Cornelis recommends that you download and install the latest versions of the CN5000 Omni-Path software and firmware. Software and Documentation are found in the Cornelis Customer Center.
To ensure optimal performance in your CN5000 fabric, it is important to review the Cornelis performance tuning recommendations in the CN5000 Performance Tuning Guide.
Issues
This section lists the resolved and open issues.
Resolved Issues
None.
Open Issues
The following table lists the open issues for this release.
ID | Description | Workaround |
|---|---|---|
STL-74370 | ASIC firmware update may fail with the following message: Error during firmware update Not that this message is seen when checking the status using the | Retry the ASIC firmware update. |
STL-73361 | On rare occasions, links connecting a CN5000 switch to an OPA100 adapter may unexpectedly bounce. | No action required, the link will self recover. |
STL-72526 | The Fabric Manager system log port numbering is different from Switch CLI command port numbering. | For details, contact support@cornelis.com for technical advisory TA0061. |
STL-71647 | On rare occasions, the link may come up at a width less than 4X. | Bounce the link. |
Product Limitations
This release has the following product limitations:
Updating the switch components (BMC/ASIC) in-band with the firmware update tool fails if the switch is running firmware older 12.2.x. You must update the firmware to 12.2 or greater before using in-band firmware updates.
Preface
This document provides an overview of the changes introduced in this release. References to more detailed information are provided where necessary. The information contained in this document is intended as supplemental information only; it should be used in conjunction with the documentation provided for each component.
Software License Agreement
The software is provided under license agreements and may contain third-party software under separate third-party licensing. Refer to the license files provided with the software for specific details.
If You Need Help
Technical support for all Cornelis products is available 24 hours a day, 365 days a year.
For additional details:
Visit the Cornelis Support page at http://www.cornelisnetworks.com/support
Contact email: support@cornelisnetworks.com
New in This Release
The following features are new in this release:
Maintenance Updates
Firmware Components
This release contains the firmware components listed in the following table.
Description | File Name | Version |
|---|---|---|
Switch Firmware | CN5000.SwitchFirmware-12.1.2.0.3-V1.pkg | 12.1.2 |
System Requirements
This section lists the supported hardware.
Supported Hardware
The following tables list the hardware supported in this release.
Hardware | Description |
|---|---|
CN5000 Switch | |
CN5000 Switch, 48-Port, CN5SWE48G2AF | 240/277 VAC in, Dual Power Supply, Air-Cooled, Fan-to-Port |
CN5000 Switch, 48-Port, CN5SWE48G2AP | 240/277 VAC in, Dual Power Supply, Air-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48G2WF | 240/277 VAC in, Dual Power Supply, Liquid-Cooled, Fan-to-Port |
CN5000 Switch, 48-Port, CN5SWE48G2WP | 240/277 VAC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48D2AP | 48 VDC in, Dual Power Supply, Air-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48D2WP | 48 VDC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan |
CN5000 Director Class Switch and Components | |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAB | 240/277 VAC in, Air-Cooled, Base Chassis |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAC | 240/277 VAC in, Air-Cooled, FRU Chassis |
CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48A | 48-Port, Air-Cooled |
CN5000 Director Class Switch, Spine Module, CN5SWDSP01A | Air-Cooled |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWB | 240/277 VAC in, Liquid-Cooled, Base Chassis |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWC | 240/277 VAC in, Liquid-Cooled, FRU Chassis |
CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48W | 48-Port, Liquid-Cooled |
CN5000 Director Class Switch, Spine Module, CN5SWDSP01W | Liquid-Cooled |
Installation Requirements
Refer to the CN5000 Maintenance and Troubleshooting Guide for instructions to update the switch firmware.
Best Practices
To obtain the most recent functional and security updates, Cornelis recommends that you download and install the latest versions of the CN5000 Omni-Path software and firmware. Software and Documentation are found in the Cornelis Customer Center.
To ensure optimal performance in your CN5000 fabric, it is important to review the Cornelis performance tuning recommendations in the CN5000 Performance Tuning Guide.
Issues
This section lists the resolved and open issues.
Resolved Issues
The following table lists the resolved issues for this release.
ID | Description | Resolved in Release |
|---|---|---|
STL-75508 | When using the node description to query, the name has a trailing space. | 12.1.0 |
STL-73399 | After rebooting the switch ASIC, port commands may show invalid information until the switch ASIC has completed initialization. | 12.1.0 |
STL-73029 | BEL DC power supplies VOUT_MODE command returns incorrect results. | 12.1.0 |
Open Issues
The following table lists the open issues for this release.
ID | Description | Workaround |
|---|---|---|
STL-74370 | ASIC firmware update may fail with the following message: Error during firmware update Not that this message is seen when checking the status using the | Retry the ASIC firmware update. |
STL-73361 | On rare occasions, links connecting a CN5000 switch to an OPA100 adapter may unexpectedly bounce. | No action required, the link will self recover. |
STL-72526 | The Fabric Manager system log port numbering is different from Switch CLI command port numbering. | For details, contact support@cornelis.com for technical advisory TA0061. |
STL-71647 | On rare occasions, the link may come up at a width less than 4X. | Bounce the link. |
Product Limitations
None.
Preface
This document provides an overview of the changes introduced in this release. References to more detailed information are provided where necessary. The information contained in this document is intended as supplemental information only; it should be used in conjunction with the documentation provided for each component.
Software License Agreement
The software is provided under license agreements and may contain third-party software under separate third-party licensing. Refer to the license files provided with the software for specific details.
If You Need Help
Technical support for all Cornelis products is available 24 hours a day, 365 days a year.
For additional details:
Visit the Cornelis Support page at http://www.cornelisnetworks.com/support
Contact email: support@cornelisnetworks.com
New in This Release
The following features are new in this release:
Maintenance Updates
Firmware Components
This release contains the firmware components listed in the following table.
Description | File Name | Version |
|---|---|---|
Switch Firmware | CN5000.SwitchFirmware-12.1.1.0.6-V1.pkg | 12.1.1.0 |
System Requirements
This section lists the supported hardware.
Supported Hardware
The following tables list the hardware supported in this release.
Hardware | Description |
|---|---|
CN5000 Switch | |
CN5000 Switch, 48-Port, CN5SWE48G2AF | 240/277 VAC in, Dual Power Supply, Air-Cooled, Fan-to-Port |
CN5000 Switch, 48-Port, CN5SWE48G2AP | 240/277 VAC in, Dual Power Supply, Air-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48G2WF | 240/277 VAC in, Dual Power Supply, Liquid-Cooled, Fan-to-Port |
CN5000 Switch, 48-Port, CN5SWE48G2WP | 240/277 VAC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48D2AP | 48 VDC in, Dual Power Supply, Air-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48D2WP | 48 VDC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan |
CN5000 Director Class Switch and Components | |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAB | 240/277 VAC in, Air-Cooled, Base Chassis |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAC | 240/277 VAC in, Air-Cooled, FRU Chassis |
CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48A | 48-Port, Air-Cooled |
CN5000 Director Class Switch, Spine Module, CN5SWDSP01A | Air-Cooled |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWB | 240/277 VAC in, Liquid-Cooled, Base Chassis |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWC | 240/277 VAC in, Liquid-Cooled, FRU Chassis |
CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48W | 48-Port, Liquid-Cooled |
CN5000 Director Class Switch, Spine Module, CN5SWDSP01W | Liquid-Cooled |
Installation Requirements
Refer to the CN5000 Maintenance and Troubleshooting Guide for instructions to update the switch firmware.
Best Practices
To obtain the most recent functional and security updates, Cornelis recommends that you download and install the latest versions of the CN5000 Omni-Path software and firmware. Software and Documentation are found in the Cornelis Customer Center.
To ensure optimal performance in your CN5000 fabric, it is important to review the Cornelis performance tuning recommendations in the CN5000 Performance Tuning Guide.
Issues
This section lists the resolved and open issues.
Resolved Issues
The following table lists the resolved issues for this release.
ID | Description | Resolved in Release |
|---|---|---|
STL-75508 | When using the node description to query, the name has a trailing space. | 12.1.0 |
STL-73399 | After rebooting the switch ASIC, port commands may show invalid information until the switch ASIC has completed initialization. | 12.1.0 |
STL-73029 | BEL DC power supplies VOUT_MODE command returns incorrect results. | 12.1.0 |
Open Issues
The following table lists the open issues for this release.
ID | Description | Workaround |
|---|---|---|
STL-74370 | ASIC firmware update may fail with the following message: Error during firmware update Not that this message is seen when checking the status using the | Retry the ASIC firmware update. |
STL-73361 | On rare occasions, links connecting a CN5000 switch to an OPA100 adapter may unexpectedly bounce. | No action required, the link will self recover. |
STL-72526 | The Fabric Manager system log port numbering is different from Switch CLI command port numbering. | For details, contact support@cornelis.com for technical advisory TA0061. |
STL-71647 | On rare occasions, the link may come up at a width less than 4X. | Bounce the link. |
Product Limitations
None.
Preface
This document provides an overview of the changes introduced in this release. References to more detailed information are provided where necessary. The information contained in this document is intended as supplemental information only; it should be used in conjunction with the documentation provided for each component.
Software License Agreement
The software is provided under license agreements and may contain third-party software under separate third-party licensing. Refer to the license files provided with the software for specific details.
If You Need Help
Technical support for all Cornelis products is available 24 hours a day, 365 days a year.
For additional details:
Visit the Cornelis Support page at http://www.cornelisnetworks.com/support
Contact email: support@cornelisnetworks.com
New in This Release
The following features are new in this release:
Maintenance Updates
Firmware Components
This release contains the firmware components listed in the following table.
Description | File Name | Version |
|---|---|---|
Switch Firmware | CN5000.SwitchFirmware-12.1.0.2.9-V1.pkg | 12.1.0.2 |
System Requirements
This section lists the supported hardware.
Supported Hardware
The following tables list the hardware supported in this release.
Hardware | Description |
|---|---|
CN5000 Switch | |
CN5000 Switch, 48-Port, CN5SWE48G2AF | 240/277 VAC in, Dual Power Supply, Air-Cooled, Fan-to-Port |
CN5000 Switch, 48-Port, CN5SWE48G2AP | 240/277 VAC in, Dual Power Supply, Air-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48G2WF | 240/277 VAC in, Dual Power Supply, Liquid-Cooled, Fan-to-Port |
CN5000 Switch, 48-Port, CN5SWE48G2WP | 240/277 VAC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48D2AP | 48 VDC in, Dual Power Supply, Air-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48D2WP | 48 VDC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan |
CN5000 Director Class Switch and Components | |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAB | 240/277 VAC in, Air-Cooled, Base Chassis |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAC | 240/277 VAC in, Air-Cooled, FRU Chassis |
CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48A | 48-Port, Air-Cooled |
CN5000 Director Class Switch, Spine Module, CN5SWDSP01A | Air-Cooled |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWB | 240/277 VAC in, Liquid-Cooled, Base Chassis |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWC | 240/277 VAC in, Liquid-Cooled, FRU Chassis |
CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48W | 48-Port, Liquid-Cooled |
CN5000 Director Class Switch, Spine Module, CN5SWDSP01W | Liquid-Cooled |
Installation Requirements
Refer to the CN5000 Maintenance and Troubleshooting Guide for instructions to update the switch firmware.
Best Practices
To obtain the most recent functional and security updates, Cornelis recommends that you download and install the latest versions of the CN5000 Omni-Path software and firmware. Software and Documentation are found in the Cornelis Customer Center.
To ensure optimal performance in your CN5000 fabric, it is important to review the Cornelis performance tuning recommendations in the CN5000 Performance Tuning Guide.
Issues
This section lists the resolved and open issues.
Resolved Issues
The following table lists the resolved issues for this release.
ID | Description | Resolved in Release |
|---|---|---|
STL-76566 | Service Channel (SC) and Virtual Lane (VLt) mapping tables are not properly programmed for subdivided child ports. | 12.1.0.2 |
STL-75508 | When using the node description to query, the name has a trailing space. | 12.1.0 |
STL-73399 | After rebooting the switch ASIC, port commands may show invalid information until the switch ASIC has completed initialization. | 12.1.0 |
STL-73029 | BEL DC power supplies VOUT_MODE command returns incorrect results. | 12.1.0 |
Open Issues
The following table lists the open issues for this release.
ID | Description | Workaround |
|---|---|---|
STL-74370 | ASIC firmware update may fail with the following message: Error during firmware update Not that this message is seen when checking the status using the | Retry the ASIC firmware update. |
STL-73361 | On rare occasions, links connecting a CN5000 switch to an OPA100 adapter may unexpectedly bounce. | No action required, the link will self recover. |
STL-72526 | The Fabric Manager system log port numbering is different from Switch CLI command port numbering. | The port number used by the FM is equivalent to twice the switch CLI port name minus one. Contact Cornelis Customer Support for details. |
STL-71647 | On rare occasions, the link may come up at a width less than 4X. | Bounce the link. |
Product Limitations
None.
Preface
This document provides an overview of the changes introduced in this release. References to more detailed information are provided where necessary. The information contained in this document is intended as supplemental information only; it should be used in conjunction with the documentation provided for each component.
Software License Agreement
The software is provided under license agreements and may contain third-party software under separate third-party licensing. Refer to the license files provided with the software for specific details.
If You Need Help
Technical support for all Cornelis products is available 24 hours a day, 365 days a year.
For additional details:
Visit the Cornelis Support page at http://www.cornelisnetworks.com/support
Contact email: support@cornelisnetworks.com
New in This Release
The following features are new in this release:
Maintenance Updates
Firmware Components
This release contains the firmware components listed in the following table.
Description | File Name | Version |
|---|---|---|
Switch Firmware | CN5000.SwitchFirmware-12.1.0.0.73-V1.pkg | 12.1.0 |
System Requirements
This section lists the supported hardware.
Supported Hardware
The following tables list the hardware supported in this release.
Hardware | Description |
|---|---|
CN5000 Switch | |
CN5000 Switch, 48-Port, CN5SWE48G2AF | 240/277 VAC in, Dual Power Supply, Air-Cooled, Fan-to-Port |
CN5000 Switch, 48-Port, CN5SWE48G2AP | 240/277 VAC in, Dual Power Supply, Air-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48G2WF | 240/277 VAC in, Dual Power Supply, Liquid-Cooled, Fan-to-Port |
CN5000 Switch, 48-Port, CN5SWE48G2WP | 240/277 VAC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48D2AP | 48 VDC in, Dual Power Supply, Air-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48D2WP | 48 VDC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan |
CN5000 Director Class Switch and Components | |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAB | 240/277 VAC in, Air-Cooled, Base Chassis |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KAC | 240/277 VAC in, Air-Cooled, FRU Chassis |
CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48A | 48-Port, Air-Cooled |
CN5000 Director Class Switch, Spine Module, CN5SWDSP01A | Air-Cooled |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWB | 240/277 VAC in, Liquid-Cooled, Base Chassis |
CN5000 Director Class Switch, 12 Leaf Slots, CN5SWD12KWC | 240/277 VAC in, Liquid-Cooled, FRU Chassis |
CN5000 Director Class Switch, Leaf QSFP112 Module, CN5SWDLQ48W | 48-Port, Liquid-Cooled |
CN5000 Director Class Switch, Spine Module, CN5SWDSP01W | Liquid-Cooled |
Installation Requirements
Refer to the CN5000 Maintenance and Troubleshooting Guide for instructions to update the switch firmware.
Best Practices
To obtain the most recent functional and security updates, Cornelis recommends that you download and install the latest versions of the CN5000 Omni-Path software and firmware. Software and Documentation are found in the Cornelis Customer Center.
To ensure optimal performance in your CN5000 fabric, it is important to review the Cornelis performance tuning recommendations in the CN5000 Performance Tuning Guide.
Issues
This section lists the resolved and open issues.
Resolved Issues
The following table lists the resolved issues for this release.
ID | Description | Resolved in Release |
|---|---|---|
STL-75508 | When using the node description to query, the name has a trailing space. | 12.1.0 |
STL-73399 | After rebooting the switch ASIC, port commands may show invalid information until the switch ASIC has completed initialization. | 12.1.0 |
STL-73029 | BEL DC power supplies VOUT_MODE command returns incorrect results. | 12.1.0 |
Open Issues
The following table lists the open issues for this release.
ID | Description | Workaround |
|---|---|---|
STL-74370 | ASIC firmware update may fail with the following message: Error during firmware update Not that this message is seen when checking the status using the | Retry the ASIC firmware update. |
STL-73361 | On rare occasions, links connecting a CN5000 switch to an OPA100 adapter may unexpectedly bounce. | No action required, the link will self recover. |
STL-72526 | The Fabric Manager system log port numbering is different from Switch CLI command port numbering. | The port number used by the FM is equivalent to twice the switch CLI port name minus one. Contact Cornelis Customer Support for details. |
STL-71647 | On rare occasions, the link may come up at a width less than 4X. | Bounce the link. |
Product Limitations
None.
Preface
This document provides an overview of the changes introduced in this release. References to more detailed information are provided where necessary. The information contained in this document is intended as supplemental information only; it should be used in conjunction with the documentation provided for each component.
Software License Agreement
The software is provided under license agreements and may contain third-party software under separate third-party licensing. Refer to the license files provided with the software for specific details.
If You Need Help
Technical support for all Cornelis products is available 24 hours a day, 365 days a year.
For additional details:
Visit the Cornelis Support page at http://www.cornelisnetworks.com/support
Contact email: support@cornelisnetworks.com
New in This Release
The following features are new in this release:
Support for the CN5000 product family as listed in Supported Hardware
Firmware Components
This release contains the firmware components listed in the following table.
Description | File Name | Version |
|---|---|---|
Switch Firmware | CN5000.SwitchFirmware-12.0.2.0.7-V1.pkg | 12.0.2 |
System Requirements
This section lists the supported hardware.
Supported Hardware
The following tables list the hardware supported in this release.
Hardware | Description |
|---|---|
CN5000 Switch, 48-Port, CN5SWE48G2AF | 240/277 VAC in, Dual Power Supply, Air-Cooled, Fan-to-Port |
CN5000 Switch, 48-Port, CN5SWE48G2AP | 240/277 VAC in, Dual Power Supply, Air-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48G2WF | 240/277 VAC in, Dual Power Supply, Liquid-Cooled, Fan-to-Port |
CN5000 Switch, 48-Port, CN5SWE48G2WP | 240/277 VAC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48D2AP | 48 VDC in, Dual Power Supply, Air-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48D2WP | 48 VDC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan |
Installation Requirements
Refer to the CN5000 Maintenance and Troubleshooting Guide for instructions to update the switch firmware.
Best Practices
To obtain the most recent functional and security updates, Cornelis recommends that you download and install the latest versions of the CN5000 Omni-Path software and firmware. Software and Documentation are found in the Cornelis Customer Center.
To ensure optimal performance in your CN5000 fabric, it is important to review the Cornelis performance tuning recommendations in the CN5000 Performance Tuning Guide.
Issues
This section lists the resolved and open issues.
Resolved Issues
None.
Open Issues
The following table lists the open issues for this release.
ID | Description | Workaround |
|---|---|---|
STL-74370 | ASIC firmware update may fail with the following message: Error during firmware update Not that this message is seen when checking the status using the | Retry the ASIC firmware update. |
STL-73399 | After rebooting the switch ASIC, port commands may show invalid information until the switch ASIC has completed initialization. | Allow time for the ASIC to complete initialization, then re-run the command. |
STL-73361 | On rare occasions, links connecting a CN5000 switch to an OPA100 adapter may unexpectedly bounce. | No action required, the link will self recover. |
STL-72526 | The Fabric Manager system log port numbering is different from Switch CLI command port numbering. | The port number used by the FM is equivalent to twice the switch CLI port name minus one. Contact Cornelis Customer Support for details. |
STL-71647 | On rare occasions, the link may come up at a width less than 4X. | Bounce the link. |
Product Limitations
None.
Preface
This document provides an overview of the changes introduced in this release. References to more detailed information are provided where necessary. The information contained in this document is intended as supplemental information only; it should be used in conjunction with the documentation provided for each component.
Software License Agreement
The software is provided under license agreements and may contain third-party software under separate third-party licensing. Refer to the license files provided with the software for specific details.
If You Need Help
Technical support for all Cornelis products is available 24 hours a day, 365 days a year.
For additional details:
Visit the Cornelis Support page at http://www.cornelisnetworks.com/support
Contact email: support@cornelisnetworks.com
New in This Release
The following features are new in this release:
Support for the CN5000 product family as listed in Supported Hardware
Firmware Components
This release contains the firmware components listed in the following table.
Description | File Name | Version |
|---|---|---|
Switch Firmware | CN5000.SwitchFirmware-12.0.1.0.1-V1.pkg | 12.0.1 |
System Requirements
This section lists the supported hardware.
Supported Hardware
The following tables list the hardware supported in this release.
Hardware | Description |
|---|---|
CN5000 Switch, 48-Port, CN5SWE48G2AF | 240/277 VAC in, Dual Power Supply, Air-Cooled, Fan-to-Port |
CN5000 Switch, 48-Port, CN5SWE48G2AP | 240/277 VAC in, Dual Power Supply, Air-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48G2WF | 240/277 VAC in, Dual Power Supply, Liquid-Cooled, Fan-to-Port |
CN5000 Switch, 48-Port, CN5SWE48G2WP | 240/277 VAC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48D2AP | 48 VDC in, Dual Power Supply, Air-Cooled, Port-to-Fan |
CN5000 Switch, 48-Port, CN5SWE48D2WP | 48 VDC in, Dual Power Supply, Liquid-Cooled, Port-to-Fan |
Installation Requirements
Refer to the CN5000 Maintenance and Troubleshooting Guide for instructions to update the switch firmware.
Best Practices
To obtain the most recent functional and security updates, Cornelis recommends that you download and install the latest versions of the CN5000 Omni-Path software and firmware. Software and Documentation are found in the Cornelis Customer Center.
To ensure optimal performance in your CN5000 fabric, it is important to review the Cornelis performance tuning recommendations in the CN5000 Performance Tuning Guide.
Issues
This section lists the resolved and open issues.
Resolved Issues
None.
Open Issues
The following table lists the open issues for this release.
ID | Description | Workaround |
|---|---|---|
STL-74370 | ASIC firmware update may fail with the following message: Error during firmware update Not that this message is seen when checking the status using the | Retry the ASIC firmware update. |
STL-73399 | After rebooting the switch ASIC, port commands may show invalid information until the switch ASIC has completed initialization. | Allow time for the ASIC to complete initialization, then re-run the command. |
STL-72526 | The Fabric Manager system log port numbering is different from Switch CLI command port numbering. | The port number used by the FM is equivalent to twice the switch CLI port name minus one. Contact Cornelis Customer Support for details. |
STL-71647 | On rare occasions, the link may come up at a width less than 4X. | Bounce the link. |
Product Limitations